Related Experiment Video
Updated: Jan 24, 2026

In vivo Bioluminescence Imaging of Tumor Hypoxia Dynamics of Breast Cancer Brain Metastasis in a Mouse Model
Published on: October 3, 2011
Volumetric Optoacoustic Imaging Unveils High-Resolution Patterns of Acute and Cyclic Hypoxia in a Murine Model of
Avihai Ron1,2, Xosé Luís Deán-Ben1,3,4, Sven Gottschalk1
1Institute for Biological and Medical Imaging, Helmholtz Center Munich, Neuherberg, Germany.
Abstract:
Mapping tumor heterogeneity and hypoxia within a living intact organism is essential for understanding the processes involved in cancer progression and assessing long-term responses to therapies. Efficient investigations into tumor hypoxia mechanisms have been hindered by the lack of intravital imaging tools capable of multiparametric probing of entire solid tumors with high spatial and temporal resolution. Here, we exploit volumetric multispectral optoacoustic tomography (vMSOT) for accurate, label-free delineation of tumor heterogeneity and dynamic oxygenation behavior. Mice bearing orthotopic MDA-MB-231 breast cancer xenografts were imaged noninvasively during rest and oxygen stress challenge, attaining time-lapse three-dimensional oxygenation maps across entire tumors with 100 μm spatial resolution. Volumetric quantification of the hypoxic fraction rendered values of 3.9% to 21.2%, whereas the oxygen saturation (sO2) rate declined at 1.7% to 2.3% per mm in all tumors when approaching their core. Three distinct functional areas (the rim, hypoxic, and normoxic cores) were clearly discernible based on spatial sO2 profiles and responses to oxygen challenge. Notably, although sO2 readings were responsive to the challenge, deoxyhemoglobin (HbR) trends exhibited little to no variations in all mice. Dynamic analysis further revealed the presence of cyclic hypoxia patterns with a 21% average discrepancy between cyclic fractions assessed via sO2 (42.2% ± 17.3%) and HbR fluctuations (63% ± 14.1%) within the hypoxic core. These findings corroborate the strong potential of vMSOT for advancing preclinical imaging of cancer and informing clinical decisions on therapeutic interventions. SIGNIFICANCE: vMSOT provides quantitative measures of volumetric hypoxic fraction and cyclic hypoxia in a label-free and noninvasive manner, providing new readouts to aid tumor staging and treatment decision making. GRAPHICAL ABSTRACT: http://cancerres.aacrjournals.org/content/canres/79/18/4767/F1.large.jpg.See related commentary by Klibanov and Hu, p. 4577.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
05:05Generating a Murine Orthotopic Metastatic Breast Cancer Model and Performing Murine Radical Mastectomy
Published on: November 29, 2018
Related Concept Videos
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Stereoisomerism of Cyclic Compounds
Fixed Action Patterns
Cyclic Processes And Isolated Systems
In the case of a non-isolated system, the change in the internal energy is zero only if the process is cyclic. A thermodynamic process is considered cyclic if the system undergoes a series of changes and returns to its initial state.
Consider a cyclic process that returns to its initial state, undergoing a four-step process. The heat transfer along each...
Voltammetric Techniques: Cyclic Voltammetry
Mouse Models of Cancer Study
The development of transgenic, knockout, and knock-in mice has led to an exponential increase in their use as model organisms in research,...