Evaluation of the Curing of Adhesive Systems by Rheological and Thermal Testing
Published on: July 3, 2020
Impact of Solvent Evaporation and Curing Protocol on Degree of Conversion of Etch-and-Rinse and Multimode Adhesives
Ceci Nunes Carvalho1, Marcos Daniel Septímio Lanza2, Letícia Gomes Dourado1
1School of Dentistry, CEUMA University, Rua Josué Montello No 1, Renascença II, 65075120 São Luís, MA, Brazil.
Objectives:
This study evaluated the effect of air-drying time and light-curing time on the degree of conversion (DC) of three etch-and-rinse adhesive systems: ONE-STEP (OS) and ONE-STEP plus (OSP), Ambar (AMB), and two multimode adhesive systems: All-Bond Universal (ABU) and ScotchBond Universal (SBU) by Fourier transform infrared (FTIR) analysis.
Materials And Methods:
The DC of each adhesive system was analyzed with six experimental different protocols: (1) immediate light curing for 10 s without solvent volatilization; (2) 10 s solvent volatilization with air stream plus 10 s light curing; (3) 60 s solvent volatilization with air stream plus 10 s light curing; (4) immediate light curing for 20 s without solvent volatilization; (5) 10 s solvent volatilization with air stream plus 20 s light curing; and (6) 60 s solvent volatilization with air stream plus 20 s light curing. FTIR spectra were obtained, and the DC was calculated by comparing the ratio of aliphatic/aromatic double carbon bonds before and after light activation (Bluephase 20i). The DC means were analyzed by three-way analysis of variance (ANOVA) and post hoc Tukey tests (α = 0.05).
Results:
Three-way ANOVA showed statistically significant adhesive, air-drying, and light-cured time (p < 0.001). In general, there was a trend of increased DC when the adhesives were dried and cured for longer times, but that was not observed for all the adhesives tested. The acetone-based adhesive systems require an air-drying prior to light activation. The light-curing time of 20 s increases the DC of all materials tested.
Conclusion:
The results suggested that the DC of the adhesive systems tested was material dependent. In general, the protocol with solvent evaporation for 10 seconds with air syringe plus 20 seconds of light curing finds the high values of DC.
More Related Videos
Related Concept Videos
Gene Conversion
Solvents
A...
Curing of Concrete
Curing Methods
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily assigned.