A Closed-Type Wireless Nanopore Electrode for Analyzing Single Nanoparticles
Published on: March 20, 2019
Single conical track-etched nanopore for a free-label detection of OSCS contaminants in heparin
Tianji Ma1, Emmanuel Balanzat2, Jean-Marc Janot1
1Institut Européen des Membranes, UMR5635 UM ENSCM CNRS, Place Eugène Bataillon, 34095, Montpellier Cedex 5, France.
Abstract:
The heparin contamination by oversulfated chondroitin (OSCS) was at the origin of one major sanitary problem of last decade. Here we propose a novel strategy to detect OSCS from heparin solution based on conical nanopore functionalized with poly-L-lysine deposition to ensure its re-usability. This sensor is an excellent to detect low heparin concentration (from 25 ng/ml to 3 μg/ml) using the modification of ionic current rectification. It also allows following the kinetic of heparin degradation by heparinase with a good correlation with results obtained by classical methods. The sensor is sensitive to the inhibition of heparinase by OSCS until a concentration of 200 pg/ml representing 0.01% in weight in a heparin. This resolution is one order of magnitude lower than the one obtained by chromatography. For the first time, it was reached without fluorescence labeling.
More Related Videos
11:55Membrane Transport Processes Analyzed by a Highly Parallel Nanopore Chip System at Single Protein Resolution
Published on: August 16, 2016
05:49Tracking Microbial Contamination in Retail Environments Using Fluorescent Powder - A Retail Delicatessen Environment Example
Published on: March 5, 2014
Related Concept Videos
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Labeling Emotion
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...