Related Experiment Video
Updated: Jan 24, 2026

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
Re-examination of accelerometer data processing and calibration for the assessment of physical activity intensity
Daniel Arvidsson1, Jonatan Fridolfsson1, Mats Börjesson1,2,3
1Department of Food and Nutrition, and Sport Science, Center for Health and Performance, University of Gothenburg, Gothenburg, Sweden.
Abstract:
This review re-examines the use of accelerometer and oxygen uptake data for the assessment of activity intensity. Accelerometers capture mechanical work, while oxygen uptake captures the energy cost of this work. Frequency filtering needs to be considered when processing acceleration data. A too restrictive filter attenuates the acceleration signal for walking and, to a higher degree, for running. This measurement error affects shorter (children) more than taller (adults) individuals due to their higher movement frequency. Less restrictive filtering includes more movement-related signals and provides measures that better capture mechanical work, but may include more noise. An optimal filter cut-point is determined where most relevant acceleration signals are included. Further, accelerometer placement affects what part of mechanical work being captured. While the waist placement captures total mechanical work and therefore contributes to measures of activity intensity equivalent by age and stature, the thigh and wrist placements capture more internal work and do not provide equivalent measures. Value calibration of accelerometer measures is usually performed using measured oxygen uptake with the metabolic equivalent of task (MET) as reference measure of activity intensity. However, the use of MET is not stringent and is not a measure of activity intensity equivalent by age and stature. A candidate measure is the mass-specific net oxygen uptake, VO2 net (VO2 tot - VO2 stand). To improve measurement of physical activity intensity using accelerometers, research developments are suggested concerning the processing of accelerometer data, use of energy expenditure as reference for activity intensity, and calibration procedure with absolute versus relative intensity.
Related Concept Videos
IR Spectrum Peak Intensity: Amount of IR-Active Bonds
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Assessment of the Gastrointestinal System I: Subjective Data
Health History
The initial step in assessing the GI system is obtaining a comprehensive health history. This includes inquiring about the patient's history or presence of problems...

