Purpose:
To measure tear clearance values in patients with meibomian gland dysfunction (MGD) with a dynamic nuclear medicine method, namely, dacryoscintigraphy (DSCI).
Methods:
Twenty-four MGD patients and 24 healthy volunteers were examined. During DSCI one drop of a solution with 100 MBq/mL99mTc sodium pertechnetate was instilled with a micropipette into the lacrimal lake of both eyes. Measurements were performed according to a dynamic data acquisition protocol, which resulted in summed DSCI images. Data were also evaluated separately in special regions of interest (ROI), and consecutive time activity curves were created. Tear clearance (T½) values were calculated based on the activity curves. In addition, tear osmolarity measurements, tear breakup time (tBUT), and Schirmer I (STI) tests were performed prior to DSCI examination.
Results:
The T½ values were 29.91 ± 11.61 min in MGD patients and 6.26 ± 1.5 min in healthy controls. Tear osmolarity parameters were 308 ± 9.41 mOsm/L and 288.9 ± 6.4 mOsm/L, tBUT values were 5.54 ± 2.73 s and 11.4 ± 2.7 s, while the STI test values were 6.17 ± 2.78 mm and 13.58 ± 3.8 mm, respectively. The differences were significant (p < 0.01) in all cases.
Conclusions:
Although the MGD patients' lacrimal drainage systems were patent their tear clearance values were significantly higher than those of healthy volunteers, which may be caused by decreased drainage of tears from the eyes towards the nasal cavity. The understanding of new features regarding the altered physico-chemical characteristics of MGD tears has been augmented by the results of this study.
Related Concept Videos
Hepatic Drug Clearance: Restrictive and Nonrestrictive Clearance
Most drugs undergo restrictive clearance, which is proportional to the...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Drug Clearance: Overview
Drug clearance is not limited to renal excretion but encompasses all organs involved in drug elimination, including...
Exocrine Glands: Unicellular and Multicellular Glands
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...