Extraction of foetal ECG from abdominal ECG by nonlinear transformation and estimations
Rolant Gini John1, K I Ramachandran2
1Department of Electronics and Communication Engineering, Amrita School of Engineering, Coimbatore, Amrita Vishwa Vidyapeetham, India.
Background And Objective:
This paper proposes a simple yet effective method for the extraction of foetal ECG from abdominal ECG which is necessary due to similar spatial and temporal content of mother and foetal ECG.
Methods:
The proposed algorithm for extraction of foetal ECG (fECG) from abdominal signal uses single channel. Pre-processing of abdominal ECG (abdECG) has been done to eliminate noise and condition the signal. The maternal ECG R-peaks have been detected based on thresholding, first order Gaussian differentiation and zero cross detection on pre-processed signal. Having identified R-peaks and pre-processed signal as base, using Maximum Likelihood Estimation, one beat including QRS complex morphology of maternal ECG (mECG) has been constructed. Extraction of maternal ECG from abdECG is done based on the constructed beat, R-peak locations and its corresponding QRS complex of abdECG. Extracted mECG has been cancelled from abdECG. This results in foetal ECG with residual noise. The noise has been reduced by Polynomial Approximation and Total Variation (PATV) to improve SNR. This approach ensures no loss of partially or completely overlapped fECG signals due to mECG removal. The algorithm is tested on three database namely daISy (DBI), Physiobank challenge 2013 (DBII) and abdominal and direct foetal ECG database (adfecgdb) of Physiobank (DBIII).
Results:
The algorithm detected no false positives or false negatives with certain channel for DBI, DBII and DBIII which shows that the proposed algorithm can achieve good performance. Overall accuracy and sensitivity of the system is 98.53% and 100% for DBI. Best accuracy and sensitivity of 97.77% and 98.63% are obtained for DBII. Best accuracy of 92.41% and sensitivity of 93.8% are obtained for DBIII. Correlation coefficient between actual foetal heart rate (fHR) and estimated fHR of 0.66 for DBII and 0.59 for DBIII is obtained. The method has obtained overall F1 score of 99.25% for DBI, 96.04% for DBII and 94.25% for DBIII. It has obtained a best MSE of fHR and overall MSE of R-R interval which is 10.8bpm2 and 2.2 ms for DBII, 12bpm2 and 2.14 ms for DBIII.
Conclusion:
The results for different public databases show that the proposed method is capable of providing good results. The foetal QRS, R-peaks and R-R intervals have also been obtained in this method. Thus, it gives a significant contribution in the required area of research.
More Related Videos
Related Concept Videos
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Bacterial Transformation
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...