Related Experiment Video
Updated: Jan 24, 2026

DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
Published on: September 28, 2021
Three-dimensional computed tomography modeling for kinematic analysis of double-strand lateral ulnar collateral
Erica Kholinne1, Tae-Hyun Ha2, Jun Tan3
1Department of Orthopedic Surgery, St Carolus Hospital, Jakarta, Indonesia; Department of Orthopedic Surgery, Asan Medical Center, College of Medicine, University of Ulsan, Seoul, Republic of Korea.
Background:
When treating posterolateral rotatory instability, the lateral ulnar collateral ligament (LUCL) is more commonly reconstructed than the other dynamic stabilizer structures. Although numerous surgical techniques have been described for LUCL reconstruction, studies have been limited to static analyses of single-strand reconstructions. The aim of this study was to dynamically analyze the kinematics of double-strand LUCL reconstructions with 3 different configurations of graft placement: horizontal, vertical, and triangular.
Methods:
Five healthy elbow joints with no signs of pre-existing pathology were scanned by computed tomography, and the images were converted into 3-dimensional models. The humeral origin and ulnar insertions of the 2 ligament strands were registered in 3-matic software for the 3 graft placement configurations. A dynamic elbow joint was simulated at 1° increments throughout the motion arc. The ligament strand lengths and the difference between them were measured.
Results:
The ligament lengths for each strand for the 3 graft configurations were as follows: horizontal, 31.0 ± 4.6 mm and 34.3 ± 5.0 mm; vertical, 32.5 ± 3.6 mm and 35.4 ± 4.2 mm; and triangular, 32.0 ± 4.0 mm and 33.7 ± 3.1 mm. The minimum length differences for the graft strands through the motion arc for the horizontal, vertical, and triangular graft configurations were 1.1, 0.0, and 1.0 mm, respectively.
Conclusions:
Dynamic analyses using a 3-dimensional elbow model showed that none of the configurations for double-strand LUCL reconstruction were isometric. However, the vertical double-strand configuration was nearly isometric and may therefore serve as a coequal option.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
09:37Extracting Metrics for Three-dimensional Root Systems: Volume and Surface Analysis from In-soil X-ray Computed Tomography Data
Published on: April 26, 2016
Related Concept Videos
Fixing Double-strand Breaks
Fixing Double-strand Breaks
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Dimensional Analysis
Dimensional analysis allows us to analyze and compare physical quantities on a...