Related Experiment Video
Updated: Jan 24, 2026

Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
Nonuniform Fourier-decomposition MRI for ventilation- and perfusion-weighted imaging of the lung
David Bondesson1,2, Moritz J Schneider1,2, Thomas Gaass3
1Department of Radiology, University Hospital, LMU Munich, Munich, Germany.
Purpose:
To improve the robustness of pulmonary ventilation- and perfusion-weighted imaging with Fourier decomposition (FD) MRI in the presence of respiratory and cardiac frequency variations by replacing the standard fast Fourier transform with the more general nonuniform Fourier transform.
Theory And Methods:
Dynamic coronal single-slice MRI of the thorax was performed in 11 patients and 5 healthy volunteers on a 1.5T whole-body scanner using a 2D ultra-fast balanced steady-state free-precession sequence with temporal resolutions of 4-9 images/s. For the proposed nonuniform Fourier-decomposition (NUFD) approach, the original signal with variable physiological frequencies that was acquired with constant sampling rate was retrospectively transformed into a signal with (ventilation or perfusion) frequency-adapted sampling rate. For that purpose, frequency tracking was performed with the synchro-squeezed wavelet transform. Ventilation- and perfusion-weighted NUFD amplitude and signal delay maps were generated and quantitatively compared with regularly sampled FD maps based on their signal-to-noise ratio (SNR).
Results:
Volunteers and patients showed statistically significant increases of SNR in frequency-adapted NUFD results compared to regularly sampled FD results. For ventilation data, the mean SNR increased by and in volunteers and patients, respectively; for perfusion data, SNR increased by and . Two patients showed perfusion signal in pulmonary areas with NUFD that could not be imaged with FD.
Conclusion:
This study demonstrates that using nonuniform Fourier transform in combination with frequency tracking can significantly increase SNR and reduce frequency overlaps by collecting the signal intensity onto single frequency bins.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Synthesis and Decomposition Reactions
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...