3D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Published on: September 19, 2025
Characterizing valve dynamics in mice by high-resolution cine-MRI
Jonna Weisell1, Anna-Kaisa Ruotsalainen2, Hanne Laakso2
1School of Pharmacy, University of Eastern Finland, Kuopio, Finland.
High-resolution cine-MRI effectively quantifies aortic valve dynamics in a mouse model of calcific aortic valve disease (CAVD). This imaging technique revealed significant aortic valve dysfunction and stenosis in mice fed a Western diet compared to controls.
Area of Science:
- Cardiovascular Imaging
- Medical Diagnostics
- Animal Models
Background:
- Calcific aortic valve disease (CAVD) involves progressive valvular sclerosis and calcification, leading to aortic orifice narrowing and impaired function.
- Accurate assessment of aortic valve dynamics is crucial for understanding CAVD progression and evaluating therapeutic interventions.
Purpose of the Study:
- To apply high-resolution cine-MRI for quantitative analysis of aortic valve dynamics in a mouse model of CAVD.
- To assess the efficacy of cine-MRI in detecting aortic valve dysfunction and stenosis in this model.
Main Methods:
- LDLr-/- ApoB100/100 mice were fed either a Western diet (WD) or a standard diet (control) for 22 weeks.
- High-resolution cine-MRI (7T scanner) was used to image the aortic valve cross-section and quantify orifice area throughout the cardiac cycle.
- MRI findings were correlated with echocardiographic and histopathologic results.
Main Results:
- Mice on the WD exhibited clear aortic valve dysfunction compared to controls (P < 0.001).
- MRI revealed significant narrowing of the aortic valve orifice area (14%, P < 0.05) and reduced ejection fraction (-11%, P < 0.01) in WD mice.
- Histology confirmed more severe aortic stenosis in WD mice (34%, P < 0.05), and MRI/echocardiography ejection fraction correlated with stenosis severity.
Conclusions:
- Cine-MRI enables quantitative analysis of aortic valve orifice dynamics over the cardiac cycle in mice.
- The technique clearly visualized aortic valve cusps and detected time-dependent aortic valve dysfunction.
- High-resolution cine-MRI is a valuable tool for assessing aortic valve disease in preclinical models.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Dynamic Equilibrium
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Mitral Valve Prolapse II: Assessment and Management
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...