Related Experiment Video
Updated: Jan 24, 2026

3D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Published on: September 19, 2025
Characterizing valve dynamics in mice by high-resolution cine-MRI
Jonna Weisell1, Anna-Kaisa Ruotsalainen2, Hanne Laakso2
1School of Pharmacy, University of Eastern Finland, Kuopio, Finland.
Aims:
In calcific aortic valve disease (CAVD), progressive valvular sclerosis and calcification cause narrowing of the orifice and an impairment of the valve's function. We applied high-resolution cine-MRI to perform quantitative analysis of the dynamics of the aortic valve in a mice model of CAVD.
Methods And Results:
LDLr-/- ApoB100/100 mice were fed a Western diet (WD) or a standard diet (control) for 22 weeks. The mice were imaged in a 7 T horizontal MRI scanner, and aortic valve dynamics was examined by imaging the cross-section of the aorta at valve level using cine sequences. From these images, the area of the aortic valve orifice was determined during the heart cycle. MRI results were compared with echocardiographic and histopathologic results. The data revealed evidence of clear aortic valve dysfunction in WD mice as compared with control mice (interaction P < 0.001). MRI showed narrowing (14%, P < 0.05) of the orifice area, and this was also seen in histology (34%, P < 0.05), indicating more severe aortic stenosis after WD than in controls. Additionally, MRI revealed a reduction in the ejection fraction (EF) (-11%, P < 0.01), a result confirmed with echocardiography (-27%, P < 0.001) in mice fed with WD. EF detected by MRI and echocardiography also correlated strongly with the degree of stenosis assessed by histology.
Conclusions:
Cine-MRI can be used for quantitative analysis of the aortic valve orifice over the cardiac cycle in mice. MRI showed the cusps clearly, and we were able to detect aortic valve dysfunction over time through the cardiac cycle.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Dynamic Equilibrium
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Mitral Valve Prolapse II: Assessment and Management
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...

