Related Experiment Video
Updated: Jan 24, 2026

Author Spotlight: Advancing SERS Technology: Au@Carbon Dot Nanoprobes for Label-Free Analysis and Imaging
Published on: June 9, 2023
Controlled Electrodeposition of Gold on Graphene: Maximization of the Defect-Enhanced Raman Scattering Response
Balakrishna Ananthoju1, Ravi K Biroju2, Wolfgang Theis2
1School of Chemistry and National Graphene Institute, University of Manchester, Oxford Road, Manchester, M13 9PL, UK.
Abstract:
A reliable method to prepare a surface-enhanced Raman scattering (SERS) active substrate is developed herein, by electrodeposition of gold nanoparticles (Au NPs) on defect-engineered, large area chemical vapour deposition graphene (GR). A plasma treatment strategy is used in order to engineer the structural defects on the basal plane of large area single-layer graphene. This defect-engineered Au functionalized GR, offers reproducible SERS signals over the large area GR surface. The Raman data, along with X-ray photoelectron spectroscopy and analysis of the water contact angle are used to rationalize the functionalization of the graphene layer. It is found that Au NPs functionalization of the "defect-engineered" graphene substrates permits detection of concentrations as low as 10-16 m for the probe molecule Rhodamine B, which offers an outstanding molecular sensing ability. Interestingly, a Raman signal enhancement of up to ≈108 is achieved. Moreover, it is observed that GR effectively quenches the fluorescence background from the Au NPs and molecules due to the strong resonance energy transfer between Au NPs and GR. The results presented offer significant direction for the design and fabrication of ultra-sensitive SERS platforms, and also open up possibilities for novel applications of defect engineered graphene in biosensors, catalysis, and optoelectronic devices.
Related Concept Videos
Electrodeposition
Electrodeposition can...
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Scatter Plot
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Self-Evaluation: Self-Enhancement and Self-Verification
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...

