Suitable interface for coupling liquid chromatography to inductively coupled plasma-mass spectrometry for the
Marie Bernardin1, Frédérique Bessueille-Barbier2, Agnès Le Masle3
1Université de Lyon, Institut des Sciences Analytiques, UMR 5280, CNRS, ENS Lyon, 5 rue de la Doua, 69100 Villeurbanne, France; IFP Energies nouvelles, Rond-point de l'échangeur de Solaize, BP 3, 69360 Solaize, France.
Abstract:
Liquid chromatography (LC) coupled with a specific detection such as inductively coupled plasma-mass spectrometry (ICP-MS/MS) is a technique of choice for elementary speciation analysis for complex matrices. The analysis of organic matrices requires the introduction of volatile solvents into the plasma which is an analytical challenge for this coupling technique. Detection sensitivity can be significantly affected by instrumental limitations. Among those, we were interested in the solute dispersion into the interface located between LC and ICP-MS/MS. This interface consists in both a Sample Introduction System (SIS) and a possible flow splitter. This study, divided into two parts, investigated the analytical performance (in terms of sensitivity and efficiency) generated by the coupling of LC and ICP-MS in the specific case of organic matrices. In Part I [1], we previously discussed the impact of extra column dispersion on the performance of LC-ICP-MS, first from a theoretical point of view and next, by assessing extra-column dispersion in 55 published studies on LC-ICP-MS. It was shown that SIS was rarely optimized with respect to its contribution to extra-column band broadening. The critical impact of flow splitting on extra-column dispersion was also pointed out. The present Part II is dedicated to the experimental comparison of commercially available SIS by assessing extra-column band broadening and hence the contribution of SIS to the loss in both efficiency and sensitivity. It is shown that the peak variance, due to SIS, can vary from 10 to 8000 μL² depending on the combination of both nebulizer and spray chamber. Whereas the highest values (i.e. > 2000 μL²) are much too high in high performance liquid chromatography (HPLC), even the lowest values (i.e. < 100 μL²) can be inappropriate in ultra-high pressure liquid chromatography (UHPLC) as highlighted in this study. In light of these results, it appears that nebulizer and spray chamber have to be chosen together with respect to the chromatographic technique (HPLC or UHPLC) and that both peak dispersion and peak intensity depend on key parameters including SIS device geometry, flow rate entering the interface or spray chamber temperature.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...