Home blood pressure in pregnancy-the upper reference limit
Marianne Vestgaard1,2, Julie Carstens Søholm1,2, Sidse Kjærhus Nørgaard1,2
1Center for Pregnant Women with Diabetes, Departments of Endocrinology and Obstetrics, Rigshospitalet, University Hospital of Copenhagen.
Objectives:
To investigate whether the upper home blood pressure reference limit in healthy pregnant women correspond to 135/85 mmHg as used when diagnosing white coat hypertension outside pregnancy.
Methods:
In this prospective observational study 103 healthy, singleton pregnant women with a mean age of 32 ± 4 (±SD) years and with a median pre-pregnancy body mass index of 21 (interquartile range 20-24) kg/m were included. Home blood pressure was measured with the device Microlife® BP 3A Plus twice daily for three days (18 measurements in total) in addition to routine office blood pressure measurements in early (median 12 (weeks)), mid (20) and late pregnancy (35). Upper blood pressure reference limits were calculated as mean +2 SD.
Results:
Office blood pressure versus home blood pressure were 115 ± 11/72 ± 7 versus 103 ± 7/64 ± 5 mmHg in early pregnancy, 112 ± 11/74 ± 7 versus 102 ± 7/63 ± 5 mmHg in mid pregnancy and 118 ± 11/75 ± 8 versus 107 ± 8/66 ± 6 mmHg in late pregnancy. The mean difference between office blood pressure and home blood pressure was 10 mmHg. In late pregnancy, the upper reference limit was 140/91 mmHg for office blood pressure and 123/78 mmHg for home blood pressure with slightly lower values in early and mid pregnancy, respectively.
Conclusion:
In late pregnancy, the upper home blood pressure reference limit in a population of healthy women was 123/78 mmHg. This value questions the generally proposed level of 135/85 mmHg to define white coat hypertension in pregnancy.
Related Concept Videos
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Measurement of Blood Pressure
Factors affecting Blood pressure
Physiological Factors:
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...