Metal Artifact Reduction in Cardiovascular MRI for Accurate Myocardial Scar Assessment in Patients With Cardiac
Mason Runge1, El-Sayed H Ibrahim2, Frank Bogun3
1University of Michigan Medical School, Ann Arbor, MI.
Abstract:
OBJECTIVE. An important application of late gadolinium enhancement (LGE) cardiac MRI is accurate assessment of myocardial scar before ablation. However, this is often limited in patients with cardiac implantable electronic devices (CIEDs) because of metal device-induced artifacts. The purpose of this study was to determine whether a modified wideband inversion recovery (IR) LGE MRI technique decreases artifact volume to allow the assessment of myocardial scar. SUBJECTS AND METHODS. Fifty patients (17 women and 33 men; mean age ± SD, 61 ± 12 years; mean ejection fraction ± SD, 35.9% ± 13.3%) with CIEDs underwent cardiac MRI using conventional and modified wideband IR LGE techniques before ablation. The volume of device-induced artifact was quantified and stratified by tertiles on mild, moderate, and severe. Ordinal logistic regression analysis assessed the association between artifact volume on conventional and wideband images adjusted for patients' demographics. RESULTS. Conventional LGE MRI resulted in device-induced hyperintense artifacts that obscured ventricular segments in 32 of 50 (64%) cases. Wideband LGE MRI significantly reduced severe artifact volume (p < 0.0001) and completely resolved all mild and most moderate artifacts. Overall, wideband techniques resulted in a 56% reduction in total artifact volume for the cohort (p < 0.0001). The wideband LGE MRI sequence minimized artifacts in the most commonly obscured segments on the conventional LGE MRI sequence, with persistent artifacts in seven, eight, and four of 32 cases at the basal anterior, midventricular anterior, and midventricular anteroseptal segments, respectively. CONCLUSION. The modified wideband IR technique completely resolves mild and moderate device-induced hyperintense artifacts and significantly reduces the volume of severe artifact to allow accurate identification of myocardial scar in patients with CIEDs before ablation.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
08:41Assessment of Cardiac Function and Myocardial Morphology Using Small Animal Look-locker Inversion Recovery SALLI MRI in Rats
Published on: July 19, 2013
Related Concept Videos
Oxidation-Reduction Reactions
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
