Related Experiment Video
Updated: Jan 24, 2026

Murine Flexor Tendon Injury and Repair Surgery
Published on: September 19, 2016
The accuracy of an injection technique for Flexor hallucis longus tendon sheath: A cadaveric study
K T M Opdam1, X Madirolas2, R Zwiers1
1Department of Orthopedic Surgery, Amsterdam UMC, Amsterdam, The Netherlands; Academic Center for Evidence based Sports medicine (ACES), Amsterdam, The Netherlands; Amsterdam Collaboration for Health and Safety in Sports (ACHSS), Amsterdam, The Netherlands.
Background:
Corticosteroid injections are used in the conservative treatment of Flexor hallucis longus (FHL) tendinopathy. Studies for imaging guided injection are done, however, the accuracy of blind injection has not yet been studied.
Purpose:
The aim of this study was to determine the accuracy of a blind injection technique into the FHL tendon sheath.
Hypothesis:
We hypothesize that a blind injections technique into the FHL tendon sheath based on clinical examination has a high accuracy.
Study Design:
Descriptive cadaveric study.
Methods:
Ten ankles of human cadavers were blindly injected with radiologic contrast mixed with methylene blue into the FHL tendon sheath. After injection, a CT scan of each ankle was performed to evaluate the location of contrast material. CT scans were reviewed by an experienced musculoskeletal radiologist blinded to the procedure. Anatomic dissection was undertaken to assess the location of the injection fluid.
Results:
In nine ankles the radiological contrast was injected in the FHL tendon sheath. In one cadaver there was a technical problem and was therefore excluded.
Conclusion:
This study shows that the FHL tendon sheath can be blindly injected based on only clinical examination with high accuracy.
Level Of Evidence:
Descriptive cadaveric study.
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...

