Related Experiment Video
Updated: Jan 24, 2026

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Comparative Analysis of Phase Lag Entropy and Bispectral Index as Anesthetic Depth Indicators in Patients Undergoing
Kwon Hui Seo1, Kyung Mi Kim2, Soo Kyung Lee1
1Department of Anesthesiology and Pain Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Korea.
Background:
Most depth of anesthesia (DOA) monitors rely on the temporal characteristics of a single-channel electroencephalogram (EEG) and cannot provide spatial or connectivity information. Phase lag entropy (PLE) reflects DOA by calculating diverse connectivity from temporal patterns of phase relationships. The aim of this study was to compare the performance of PLE and bispectral index (BIS) monitors for assessing DOA during anesthesia induction, nerve integrity monitoring (NIM), and anesthesia emergence.
Methods:
Thirty-five patients undergoing elective thyroid surgery with recurrent laryngeal nerve NIM received propofol and remifentanil via target-controlled infusion. After applying PLE and BIS monitors, propofol infusion was initiated at a calculated effect site concentration (Ce) of 2 μg/mL and then increased in 1-μg/mL Ce increments. After propofol Ce reached 5 μ/mL, a remifentanil infusion was begun, and anesthesia induction was considered complete. During NIM, PLE and BIS values were compared at a specific time points from platysma muscle exposure to subcutaneous tissue closure. PLE and BIS values were recorded continuously from preanesthetic state to full recovery of orientation; bias and limits of agreement between monitors were calculated.
Results:
PLE and BIS values decreased progressively with increasing propofol Ce during anesthetic induction and increased by stages during emergence. The prediction probabilities of PLE and BIS for detecting propofol Ce changes were 0.750 and 0.756, respectively, during induction and 0.749 and 0.746, respectively, during emergence. No aberrant PLE or BIS values occurred during NIM. Correlation coefficients for BIS and PLE were 0.98 and 0.92 during induction and emergence, respectively. PLE values were significantly higher than BIS values at full recovery of orientation. Estimated bias between monitors was -4.16 ± 8.7, and 95% limits of agreement were -21.21 to 12.89.
Conclusion:
PLE is a reasonable alternative to BIS for evaluating consciousness and DOA during general anesthesia and during NIM.
Trial Registration:
Clinical Research Information Service Identifier: KCT0003490.
More Related Videos
04:42A Personalized 3D-Printed Model for Preoperative Evaluation in Thyroid Surgery
Published on: February 17, 2023
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
Related Concept Videos
Entropy
Entropy
When an ideal gas expands isothermally, the disorder in the gas increases. From the molecular perspective, the gas molecules have more volume to move around in.
Consider an infinitesimal step in the expansion, which...
Phase-lead and Phase-lag Controllers
Standard Entropy Change for a Reaction
Lagging Strand Synthesis
There are several major differences between synthesis of the leading strand and synthesis of the lagging strand. 1) Leading strand synthesis happens in the direction of replication fork opening, whereas lagging strand synthesis happens in the...
Indicators