Rapid and Automated Detection of Six Contaminants in Milk Using a Centrifugal Microfluidic Platform with Two Rotation

Yiqi Chen1,2, Yunzeng Zhu1,2, Minjie Shen1,2

  • 1State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine , Tsinghua University , Beijing 100084 , China.

Related Concept Videos

Relative Motion Analysis using Rotating Axes - Acceleration01:22

Relative Motion Analysis using Rotating Axes - Acceleration

Consider a component AB undergoing a linear motion. Along with a linear motion, point B also rotates around point A. To comprehend this complex movement, position vectors for both points A and B are established using a stationary reference frame. The absolute velocity of point B is determined by adding the absolute velocity of point A, the relative velocity of point B in the rotating frame, and the effects caused by the angular velocity within the rotating frame.
Time differentiation is...
771
Relative Motion Analysis using Rotating Axes01:25

Relative Motion Analysis using Rotating Axes

Consider a component AB undergoing a linear motion. Along with a linear motion, point B also rotates around point A. To comprehend this complex movement, position vectors for both points A and B are established using a stationary reference frame.
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
894
Relative Motion Analysis using Rotating Axes-Problem Solving01:29

Relative Motion Analysis using Rotating Axes-Problem Solving

Consider a crane whose telescopic boom rotates with an angular velocity of 0.04 rad/s and angular acceleration of 0.02 rad/s2. Along with the rotation, the boom also extends linearly with a uniform speed of 5 m/s. The extension of the boom is measured at point D, which is measured with respect to the fixed point C on the other end of the boom. For the given instant, the distance between points C and D is 60 meters.
Here, in order to determine the magnitude of velocity and acceleration for point...
707
Centrifugation01:05

Centrifugation

Centrifugation is a separation technique based on differences in density or size. It is commonly used to separate solids from aqueous interferents. During centrifugation, the sample is placed in centrifugation tubes and spun at high angular velocity, which allows centrifugal force to act differentially on the different densities or masses of the components. After spinning, the supernatant liquid is decanted. Depending on the specific application, either the pellet or the supernatant is retained...
7.0K
Contaminants and Errors01:16

Contaminants and Errors

Effective sample preparation is crucial for accurate and reliable laboratory analysis. During this process, two significant sources of error can arise: concentration bias from improper sample splitting and contamination caused by methods used to reduce particle size, such as grinding or homogenization. Identifying and minimizing these potential errors is crucial to ensuring the validity of the analysis.
Another key consideration is determining the appropriate number of samples required to...
352
Moments of Inertia for an Area about Inclined Axes01:18

Moments of Inertia for an Area about Inclined Axes

In physics and engineering, understanding the moments of inertia for a given area with asymmetrical mass distribution is critical for proper design and analysis. When considering an arbitrary coordinate system, the moments of inertia can be obtained by integrating the moment of inertia for an infinitesimal area element.
1.1K