Rapid and Automated Detection of Six Contaminants in Milk Using a Centrifugal Microfluidic Platform with Two Rotation Axes
Related Experiment Video
Updated: Jan 24, 2026

Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood
Published on: April 16, 2016
Yiqi Chen1,2, Yunzeng Zhu1,2, Minjie Shen1,2
1State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine , Tsinghua University , Beijing 100084 , China.
Abstract:
Antibiotic residues and illegal additives are among the most common contaminants in milk and other dairy products, and they have become essential public health concerns. To ensure the safety of milk, rapid and convenient screening methods are highly desired. Here, we integrated microarray technology into a microfluidic device to achieve rapid, sensitive, and fully automated detection of chloramphenicol, tetracyclines, enrofloxacin, cephalexin, sulfonamides, and melamine in milk on a centrifugal microfluidic platform with two rotation axes. All the liquid reagent for the immunoassay was prestored in the reagent chambers of the microdevice and can be released on demand. The whole detection can be automatically accomplished within 17 min, and the limits of detection were defined as 0.92, 1.01, 1.83, 1.14, 1.96, and 7.80 μg/kg for chloramphenicol, tetracycline (a typical drug of tetracyclines), enrofloxacin, cephalexin, sulfadiazine (a typical drug of sulfonamides), and melamine, respectively, satisfying the national standards for maximum residue limits in China. Raw milk samples were used to test the performance of the current immunoassay system, and the recovery rates in the repeatability tests ranged from 80 to 111%, showing a good performance. In summary, the immunoassay system established in this study can simultaneously detect six contaminants of four samples in a fully automated, cost-effective, and easy-to-use manner and thus has great promise as a screening tool for food safety testing.
Related Concept Videos
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Centrifugation
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Moments of Inertia for an Area about Inclined Axes