Monitoring of acoustic cavitation in microbubble-presented focused ultrasound exposure using gradient-echo MRI
Chen-Hua Wu1, Hao-Li Liu2,3, Cheng-Tao Ho1
1Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan.
Background:
Gadolinium-based contrast agents can be used to identify the blood-brain barrier (BBB) opening after inducing a focused ultrasound (FUS) cavitation effect in the presence of microbubbles. However, the use of gadolinium may be limited for frequent routine monitoring of the BBB opening in clinical applications.
Purpose:
To use a gradient-echo sequence without contrast agent administration for monitoring of acoustic cavitation.
Study Type:
Animal and phantom prospective.
Phantom/Animal Model:
Static and flowing gel phantoms; six normal adult male Sprague-Dawley rats.
Field Strength/Sequence:
3T, 7T; fast low-angle shot sequence.
Assessment:
Burst FUS with acoustic pressures = 1.5, 2.2, 2.8 MPa; pulse repetition frequencies = 1, 10,100 Hz; and duty cycles = 2%, 5%, 10% were transmitted to the chamber of a static phantom with microbubble concentrations = 10%, 1%, 0.1%. MR slice thicknesses = 3, 6, 8 mm were acquired. In flowing phantom experiments, 0.1%, 0.25%, 0.5%, 0.75%, and 1% microbubbles were infused and transmitted by burst FUS with an acoustic pressure = 0.4 and 1 MPa. In in vivo experiments, 0.25% microbubbles was infused and 0.8 MPa burst FUS was transmitted to targeted brain tissue beneath the superior sagittal sinus. The mean signal intensity (SI) was normalized using the mean SI from pre-FUS.
Statistical Tests:
Two-tailed Student's t-test. P < 0.05 was considered statistically significant.
Results:
In the static phantom, the time courses of normalized SI decreases to minimum SI levels of 70-80%. In the flowing phantom, substantial normalized SI of 160-230% was present with variant acoustic pressures and microbubble concentrations. Compared with in vivo control rats, the brain tissue of experimental rats with transmission of FUS pulses exhibited considerable decreases of normalized SI (P < 0.001) because of the cavitation-induced perturbation of flow.
Data Conclusion:
Observing gradient-echo SI changes can help monitor the targeted location of microbubble-enhanced FUS, which in turn assists the monitoring of the BBB opening.
Level Of Evidence:
2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:311-318.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Energy Line and Hydraulic Gradient Line
Gradient and Del Operator
Focusing of Light in the Eye