Part per quadrillion quantitation of pentaerythritol tetranitrate vapor using online sampling gas chromatography-mass
Matthew Mullen1, Braden C Giordano2
1NRC Post-Doctoral Fellow at US Naval Research Laboratory Washington, D.C., USA.
Abstract:
The development of an online sampling method using programmable temperature vaporization gas chromatography with a mass spectrometer detector (PTV-GC/MS) for the analysis of trace pentaerythritol tetranitrate (PETN) vapor is presented. PETN degradation was minimized by optimizing the temperature and flow rates of the vapor sampling infrastructure. Validation of the online method was done using a previously published technique, vapor sampling with Tenax-TA thermal desorption tubes followed by analysis with a thermal desorption system coupled to a programmable temperature vaporization gas chromatograph with a micro-electron capture detector (TDS-PTV-GC/μECD). Trace PETN vapor was generated using state-of-the-art instrumentation known as the TESTbed, located at the US Naval Research Laboratory. For PETN vapor concentrations in the parts per trillionvolume (pptv) range, quantitative results from the TDS-PTV-GC/μECD consistently showed concentrations approximately double that measured by the online PTV-GC/MS method, indicating that sample loss due to additional exposure to the vapor sampling infrastructure occurs when using online sampling. Further utilization of the online PTV-GC/MS system allowed for the quantitation/semi-quantitation of PETN vapor concentrations as low as 260 parts per quadrillionvolume (ppqv) with only 10 min of sampling time.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Vaporization
Vapor Pressure
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...