Related Experiment Video
Updated: Jan 24, 2026

Author Spotlight: Optimizing CFU Determination for Efficient Assessment of TB Vaccine Efficacy and Antigen Presentation Analysis
Published on: July 28, 2023
Enhanced manual cleaning efficacy of duodenoscope in endoscopy units: Results of a multicenter comprehensive quality
Wei-Kuo Chang1, Tao-Chieh Liu1, Tzu-Ling Liu2
1Division of Gastroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan.
Background:
Multiple outbreaks from contaminated duodenoscopes have been reported since 2008. This study assessed results of a multicenter comprehensive quality control (QC) program to enhance manual cleaning efficacy of duodenoscopes in endoscopy units.
Methods:
Digestive Endoscopy Society of Taiwan implemented a QC program with adenosine triphosphate (ATP) testing of patient-used duodenoscopes in 2 rounds of on-site audit in endoscopy units. ATP samples were obtained from 5 different locations of the duodenoscope after manual cleaning. Duodenoscope exceeding ATP benchmark of 200 relative light units indicated inadequate manual cleaning.
Results:
During the first round on-site audit, 12 hospitals and 27 patient-used duodenoscopes were analyzed. Distal end outer surface (29.6%), elevator mechanism (51.9%), distal attachment cap (59.3%), elevator wire channel (37.0%), and suction biopsy channel (37.0%) were inadequately cleaned. Overall, 19 (70.4%) duodenoscopes had inadequate manual cleaning, ranging widely from 0%-100% among endoscopy units. During the follow-up on-site audit, 32 patient-used duodenoscopes were analyzed, and 6 (18.8%) had inadequate manual cleaning.
Conclusions:
ATP tests may provide real-time feedback on the cleaning efficacy of patient-used duodenoscopes. Implementing a comprehensive QC program could enhance the efficacy of manual cleaning in endoscopy units.
Related Concept Videos
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Measurement: Standard Units
Measurement: Derived Units
Self-Efficacy
Motor Units