Related Experiment Video
Updated: Jan 24, 2026

Three-Dimensional Printing Guide Template Assisted Percutaneous Vertebroplasty PVP
Published on: October 17, 2019
Comparative study of sacroiliac screw placement guided by 3D-printed template technology and X-ray fluoroscopy
1Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Objective:
To compare the clinical effect of 3D-printed template technology with X-ray fluoroscopy in assisting surgery for sacroiliac screws placement.
Design:
Institutional review board-approved retrospective analysis.
Patients:
The clinical data of 31 cases of sacroiliac complex injury between January 2015 and December 2016 were analyzed. There were 16 patients, males 11 and females 5, who underwent surgery assisted by 3D-printed template in template group, and that of contemporaneous 15 patients, males 11 and females 4, who underwent traditional surgery were gathered as fluoroscopy group. All those patients were followed up for more than 6 months.
Main Outcome Measures:
The operation time and X-ray fluoroscopy times for each screw placement, and the Matta and Majeed score were analyzed and the difference between the two group was tested.
Results:
All cases were followed up for 6-20 months, average 11.4 ± 0.6 months. In template group, 19 screws were implanted. Each screw spent 25-38 min, average 27.2 ± 5.3 min, and need 2-5 times fluoroscopy, average 2.7 ± 0.5. The fracture reduction quality was evaluated by Matta score scale: excellent 10, well 4, fair 2, good rate 87.5%; and pelvic function were evaluated by Majeed score scale: excellent 11, well 3, fair 2, and good rate 87.5%. In fluoroscopy group, 17 screws were implanted. Each screw spent 45-70 min, average 60.3 ± 5.8 min, and needs 11-23 times fluoroscopy, average 15.4 ± 3.5. The fracture reduction quality was evaluated by Matta score scale: excellent 7, well 6, fair 2, and good rate 86.7%; and pelvic function was evaluated by Majeed score scale: excellent 6, well 6, fair 3, and good rate 80.0%. The difference in operation time, X-ray fluoroscopy times between template group and fluoroscopy group had statistical significance. But the Matta and Majeed score had no difference between two groups.
Conclusion:
Compared with traditional surgery, 3D-printed template technology-assisted surgery for sacroiliac screws placement in sacroiliac complex injury patients possesses advantage such as shortened operation time and reduced X-ray exposure times. This technology improves the safety profile of this operation and should be further studied in future clinical applications.
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
DNA as a Genetic Template
DNA as a Genetic Template
Screw: Problem Solving
To evaluate the...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

