Related Experiment Video
Updated: Jan 24, 2026

Measuring Fluxes of Mineral Nutrients and Toxicants in Plants with Radioactive Tracers
Published on: August 22, 2014
Approximate nutrient flux and concentration solutions of the Nye-Tinker-Barber model by the perturbation expansion
1Fujian Provincial Key Laboratory of Mathematical Analysis and its Applications, College of Mathematics and Informatics, Fujian Normal University, Qishan Campus, Fuzhou 350117, China.
Abstract:
The Nye-Tinker-Barber model is a basic and representative one for single-ion nutrient uptake by plant root from the soil and we aim to derive its approximate analytical solutions of flux and concentration. We divide the rhizosphere into the inner and the outer fields, match the inner and the outer solutions near the root surface, and then obtain the approximate analytical solutions of nutrient uptake flux at the root surface and global nutrient concentration of the diffusion or the convection-diffusion Nye-Tinker-Barber model. The analytical and numerical fluxes of K+ and [Formula: see text] decay quickly to 0 in less than 3 days while [Formula: see text] and Cd2+ gradually decrease in more than 15 days; the depletion profile spread of [Formula: see text] is apparently narrower than [Formula: see text] and K+ in 24 days. The different flux and concentration patterns of 4 nutrients result from their mobility and solubility in the rhizosphere. In comparison with the numerical simulations and the previous analytical results, we find that the analytical flux will overestimate the numerical flux of [Formula: see text] and Cd2+ while the analytical concentration can accurately predict the numerical concentration; the flux and the concentration solutions of the convection-diffusion Nye-Tinker-Barber model can be simplified to the diffusion versions by the Péclet number, and they can more widely describe the transport of nutrients of different attributes in soils of different textures with different levels of saturation, conductivity and permeability.
Related Concept Videos
Solution Concentration and Dilution
Expressing Solution Concentration
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
Linearization and Approximation
Application of Linearization and Approximation
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Weak Acid Solutions

