Left ventricular assist device implantation may be feasible in appropriately selected patients with severe renal
Chetan Pasrija1, Douglas Tran2, Praveen George2
1Division of Cardiac Surgery, University of Maryland School of Medicine, Baltimore, Md.
Objectives:
Severe renal insufficiency is considered a relative contraindication to left ventricular assist device (LVAD) implantation. After establishing an algorithmic approach to these patients, we hypothesized that LVAD implantation with severe renal insufficiency could be performed without increasing morbidity or mortality.
Methods:
All consecutive patients (July 2015-December 2017) who underwent LVAD implantation were retrospectively reviewed. Patients were stratified by preoperative glomerular filtration rate (GFR): ≤30 mL/min/1.73 m2 (low-GFR) and >30 mL/min/1.73 m2 (high-GFR). Preoperative optimization included aggressive inotropic support and temporary mechanical circulatory support before LVAD implantation in any patient with an acute component of renal insufficiency. All patients with a preoperative GFR ≤15 mL/min/1.73 m2 were prophylactically initiated on temporary renal replacement therapy postoperatively. The primary outcome was Kaplan-Meier 1-year survival.
Results:
Fifty-eight patients (21 with low-GFR and 37 with high-GFR) were identified. Patients in the low-GFR cohort had a significantly higher median Interagency Registry for Mechanically Assisted Circulatory Support score and worse preoperative end-organ function. Preoperative optimization resulted in an increase in GFR to >30 mL/min/1.73 m2 in 11 out of 21 patients from the low-GFR cohort. Inotrope days, ventilator time, intensive care unit length of stay, and hospital length of stay were not significantly different between the groups. Kaplan-Meier 1-year survival was 81% in the low-GFR cohort and 86% in the high-GFR cohort (P = .98). Subset analysis of GFR ≤15 mL/min/1.73 m2 (n = 11) and ≥60 mL/min/1.73 m2 (n = 19) demonstrated identical 1-year survival (89% vs 89%; P = .91).
Conclusions:
LVAD implantation in carefully selected patients with severe renal insufficiency can be performed without increasing midterm morbidity or mortality. This strategy may serve as a successful option to bridge patients to transplantation or destination therapy.
Related Concept Videos
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
What is Natural Selection?
Renal Corpuscle
Glomerulus: Structure and Function
The glomerulus is a tiny, intricate network of capillaries located at the beginning of the nephron. It's enveloped by the Bowman's capsule and receives its blood supply from an afferent arteriole, which divides into numerous...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Antibiotic Selection