2-Year Clinical Outcomes of an Abluminal Groove-Filled Biodegradable-Polymer Sirolimus-Eluting Stent Compared With a
Bo Xu1, Yuichi Saito2, Andreas Baumbach3
1Fu Wai Hospital, National Centre for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China.
Objectives:
The aim of this study was to assess the 2-year clinical outcomes of the Firehawk stent (Shanghai MicroPort Medical Group, Shanghai, China), a novel abluminal groove-filled biodegradable-polymer sirolimus-eluting coronary stent, compared with XIENCE (Abbott Vascular, Santa Clara, California), a durable-polymer everolimus-eluting coronary stent.
Background:
The long-term outcomes of the Firehawk stent have not been evaluated beyond 1 year in a randomized all-comers clinical trial.
Methods:
The TARGET All Comers study is a prospective, multicenter, all-comers, randomized, noninferiority trial conducted in Europe. A total of 1,653 patients were randomly assigned to undergo implantation of either the Firehawk or the XIENCE stent. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization.
Results:
At 2-year follow-up, the incidence of target lesion failure was 8.7% in the Firehawk group versus 8.6% in the XIENCE group (p = 0.92). The event rates of individual components of the primary endpoint were comparable for the 2 groups. Landmark analyses between 1- and 2-year follow-up revealed no statistically significant difference of TLF for the Firehawk versus the XIENCE stent. Beyond 1 year, very late definite or probable stent thrombosis occurred in 3 patients (0.4%) in the Firehawk group and in 7 patients (0.9%) in the XIENCE group (p = 0.34).
Conclusions:
The 2-year follow-up of the TARGET All Comers study confirms comparable safety and efficacy profiles of the Firehawk and XIENCE stents.
More Related Videos
Related Concept Videos
Polymers
Polymers
High-Performance Liquid Chromatography: Elution Process
Polymer Classification: Architecture
Polymer Classification: Crystallinity
Crystalline domains are the regions where polymer chains are aligned in an orderly manner and held together in proximity by intermolecular forces. For example, chains in the crystalline domains of polyethylene and nylon are bound together by van der Waals...
Polymer Classification: Stereospecificity