Related Experiment Video
Updated: Jan 24, 2026

Graphene Coatings for Biomedical Implants
Published on: March 1, 2013
Characteristics of different cathodic arc deposition coatings on CoCrMo for biomedical applications
Joachim Döring1, Maria Crackau1, Christian Nestler2
1Department of Orthopaedic Surgery, Medical Faculty, Otto-von-Guericke-University Magdeburg, Leipziger Straße 44, 39120, Magdeburg, Germany.
Abstract:
Coatings of endoprostheses are used to improve the tribological performance of arthroplasties. A major challenge for the successful use of these coatings, however, is a stable layer adhesion, a smooth surface, as well as a reduction in droplet formation during the coating process. Explants with commercially available coatings were investigated to assess surface/layer defects and adhesion properties. For the investigation of new coatings, we used cathodic arc deposition (Arc-PVD) to generate TiN, ZrN similar to the currently commercially available coatings and three different diamond like carbon (DLC) coatings on CoCrMo substrate. All surface coatings were mechanically specified by measuring roughness, coating thickness, abrasive wear and critical loads. A friction wear test was modified using an UHMWPE counterpart with a contact pressure of 10 MPa to compare different coatings in one tribological test setup. Calf serum was used as lubricant. The commercially used coatings on the retrieved explants show several defects and the critical load for coating failure varied widely. All produced surface coatings showed an increased surface roughness after coating compared to uncoated samples, which was due to droplet formation, especially in the DLC coatings. A diamond post-polishing process was performed to reduce the surface roughness and reach the ISO standard of Ra < 50 nm. The ZrN and TiN coatings exhibited a decreased friction after removing of the droplets in comparison to uncoated CoCrMo samples, indicating that the post-polishing process might be a useful tool to ameliorate the tribological performance. The friction coefficient for all tested DLC layers was more than two times increased compared to the CoCrMo samples. The use of hard/soft bearings with DLC coated endoprostheses seems to be not advantageous.
More Related Videos
Related Concept Videos
Characteristics of Life
Phase Transitions: Sublimation and Deposition
Characteristics of Fluids
Characteristics of Fluids
Fluids, which include both liquids and gases, are substances that deform continuously under shearing stress. For example, water and oil are liquids with molecules that can...
Characteristics of BJT
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...
Characteristics of JFET
The core of a JFET's operation is controlling drain current by modulating the gate-source voltage. When the drain and gate voltage are set to zero, the JFET exhibits no net current flow, representing a state of equilibrium. The drain current increases linearly as the...

