Analysis of noise pollution emitted by stationary MF285 tractor using different mixtures of biodiesel, bioethanol,
Mohammad Ghaderi1, Hossein Javadikia2, Leila Naderloo1
1Department of Mechanical Biosystems Engineering, Faculty of Agriculture, College of Agriculture and Natural Science, Razi University, Kermanshah, 67571, Iran.
Abstract:
In the present study, the noise pollution from different compositions of biodiesel, bioethanol, and diesel fuels in a four-cylinder and four-stroke engine of MF285 tractor was studied. Further, the noise pollution was measured from two positions, the driver and bystander, at 1000, 1600, and 2000 revolutions, and ten different fuel levels resulting from different compositions of biodiesel, bioethanol, and diesel fuels. For data analysis, adaptive network-based fuzzy inference system (ANFIS), artificial neural network (ANN), and response surface methodology (RSM) were applied. Comparing the means of noise pollution at different levels demonstrated that the B25E6D69 fuel, made up of 25% biodiesel and 6% bioethanol, had the lowest noise pollution. The lowest noise pollution was at 1000 rpm, and with the increase of engine speed, the noise pollution intensified. The models laid by the RSM were better than other.
More Related Videos
09:10Experimental Protocol for Biodiesel Production with Isolation of Alkenones as Coproducts from Commercial Isochrysis Algal Biomass
Published on: June 24, 2016
05:33Introduction of an Integrated Pathology Image Management, Artificial Intelligence, and Reporting System
Published on: July 11, 2025
Related Concept Videos
Mixtures of Acids
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
Mixtures of Acids
In a strong and weak acid mixture, the strong acid dissociates completely and becomes a source of almost all the hydronium ions present in the solution. In contrast, the weak acid shows...
Otto and Diesel Cycle
Intelligence
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Measures of Intelligence
Validity refers to how well a test measures what it claims to measure. An intelligence test should accurately assess intelligence rather than another characteristic, like anxiety. Criterion validity is one way to evaluate this;...