Diagnostic utility of hybrid single photon emission computed tomography/computed tomography imaging in patients with Takotsubo syndrome
Related Experiment Video
Updated: Jan 24, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Małgorzata Kobylecka1, Monika Budnik2, Janusz Kochanowski2
1Nuclear Medicine Department.
Purpose:
Clinical symptoms and electrocardiographic changes in patients with Takotsubo syndrome can be similar to patients with myocardial infarction. The aim of the study was to assess the impact of SPECT/CT imaging on the diagnosis and management of Takotsubo syndrome (TTS).
Methods:
Gated single photon emission computed tomography (SPECT)/CT after injection 99Tc-MIBI in resting conditions was performed in 27 patients with TTS using dual-head Symbia T6SPECT/CT hybrid device. CT data were used for attenuation correction of SPECT images and to assess the risk of coronary artery disease on the basis of coronary artery calcium score.
Results:
Abnormal myocardial perfusion was found in 20/27 patients. The mean defect size was 9.8 cm, the extent 11.7%, mean total perfusion defect was 10.36%, mean summed rest score (SRS) 6.71.Left ventricle ejection fraction was lower in patients with SRS at least 4 than in patients with SRS less than 4. Perfusion defect size, total perfusion defect, number of akinetic segments in echocardiography and number of segments with perfusion defect in SPECT were higher in the group with SRS at least 4. The applied attenuation correction algorithms did not change the result of our SPECT study.
Conclusion:
In the majority of patients with TTS perfusion in SPECT was normal or only minor perfusion defect was observed. Application of CT attenuation correction did not change the final result of myocardial perfusion imaging; therefore, the CT component of the SPECT/CT study performed for attenuation correction is not useful for TTS diagnosis.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Design Example: Traverse Angle Computations