A Tool for Automatic Correction of Endogenous Concentrations: Application to BHB Analysis by LC-MS-MS and GC-MS
Brigitte Desharnais1,2, Marie-Jo Lajoie1, Julie Laquerre1
1Laboratoire de sciences judiciaires et de médecine légale, Department of Toxicology, 1701 Parthenais Street, Montréal, Québec, Canada.
Abstract:
Several substances relevant for forensic toxicology purposes have an endogenous presence in biological matrices: beta-hydroxybutyric acid (BHB), gamma-hydroxybutyric acid (GHB), steroids and human insulin, to name only a few. The presence of significant amounts of these endogenous substances in the biological matrix used to prepare calibration standards and quality control samples (QCs) can compromise validation steps and quantitative analyses. Several approaches to overcome this problem have been suggested, including using an analog matrix or analyte, relying entirely on standard addition analyses for these analytes, or simply ignoring the endogenous contribution provided that it is small enough. Although these approaches side-step the issue of endogenous analyte presence in spiked matrix-matched samples, they create serious problems with regards to the accuracy of the analyses or production capacity. We present here a solution that addresses head-on the problem of endogenous concentrations in matrices used for calibration standards and quality control purposes. The endogenous analyte concentration is estimated via a standard-addition type process. This estimated concentration, plus the spiked concentration are then used as the de facto analyte concentration present in the sample. These de facto concentrations are then used in data analysis software (MultiQuant, Mass Hunter, etc.) as the sample's concentration. This yields an accurate quantification of the analyte, free from interference of the endogenous contribution. This de facto correction has been applied in a production setting on two BHB quantification methods (GC-MS and LC-MS-MS), allowing the rectification of BHB biases of up to 30 μg/mL. The additional error introduced by this correction procedure is minimal, although the exact amount will be highly method-dependent. The endogenous concentration correction process has been automated with an R script. The final procedure is therefore highly efficient, only adding four mouse clicks to the data analysis operations.
More Related Videos
08:39High-throughput Image Analysis of Tumor Spheroids: A User-friendly Software Application to Measure the Size of Spheroids Automatically and Accurately
Published on: July 8, 2014
08:54In vivo Application of the REMOTE-control System for the Manipulation of Endogenous Gene Expression
Published on: March 29, 2019
Related Concept Videos
Automatic Processing and Automatic Social Behavior
Distance Corrections
Power Factor Correction
Overview of Microsoft Excel as a Data Analysis Tool
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Concentration Cells
Consider the following voltaic cell: