Related Experiment Video
Updated: Jan 24, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Network meta-analysis of new-generation valves for transcatheter aortic valve implantation
Hisato Takagi1,2, Yosuke Hari3,4, Kouki Nakashima3,4
1Department of Cardiovascular Surgery, Shizuoka Medical Center, 762-1 Nagasawa, Shimizu-cho, Sunto-gun, Shizuoka, 411-8611, Japan. kfgth973@ybb.ne.jp.
Abstract:
To comprehensively compare and rank new-generation valves (NGVs) for transcatheter aortic valve implantation, we performed a network meta-analysis (NMA) of all eligible comparative studies. MEDLINE and EMBASE were searched through September 2018. We included all studies comparing 4 NGVs (ACURATE, Evolut R, Lotus, and SAPIEN 3) and an early generation valve (CoreValve) as the reference transcatheter heart valve (THV) each other and reporting at least one of postprocedural incidence of all-cause death, ≥ moderate aortic regurgitation (AR), and new permanent pacemaker implantation (PMI). To compare different THVs, a random-effects restricted-maximum-likelihood NMA based on a frequentist framework for indirect and mixed comparisons was used. Using surface under the cumulative ranking curve (SUCRA), the relative ranking probability of each THV was estimated and the hierarchy of competing THVs was obtained. We identified 29 eligible studies enrolling a total of 17,817 patients. In accordance with the estimated SUCRA probability, SAPIEN 3 was the best effective for a reduction in death (80.6%) and the second best for decreased ≥ moderate AR (74.4%) and PMI (74.1%) compared with the other THVs. Lotus was ranked the best for a reduction in ≥ moderate AR (94.5%;), whereas the worst for decreased PMI (1.2%) and the second worst for a reduction in mortality (38.6%). ACURATE was the best for decreased PMI (99.2%) and the second best for a reduction in mortality (77.9%). As a whole, SAPIEN 3 may be the best effective NGV among the 4 examined NGVs (ACURATE, Evolut R, Lotus, and SAPIEN 3).
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Protein Networks
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...
Protein Networks