Related Experiment Video
Updated: Jan 24, 2026

Online Size-exclusion and Ion-exchange Chromatography on a SAXS Beamline
Published on: January 5, 2017
Hb Aalesund (HBA2: c.400_406delAGCACCG), an Unstable α-Globin Variant Found in a Norwegian Patient Causing Moderate
Runa M Grimholt1,2,3, Bente Fjeld1,2, Hilde Selsås4
1a Department of Medical Biochemistry , Oslo University Hospital, Ullevaal , Oslo , Norway.
A new unstable hemoglobin (Hb) variant, named Hb Aalesund, was detected during Hb A1c measurement in a patient with a nearly compensated hemolytic anemia. Sequencing of the α-globin genes revealed a 7 bp deletion in exon 3 of the HBA2 gene (HBA2: c.400_406delAGCACCG) (NM_000517.4) causing a frameshift and a premature termination codon (PTC) two positions downstream. Apparently, the transcript bypassed nonsense-mediated decay (NMD), and a truncated protein was translated. The unstable Hb variant presumably underwent rapid denaturation, as heterozygosity of Hb Aalesund was associated with mild hemolytic anemia. In addition, the Hb variant interfered with Hb A1c measurement by cation exchange high performance liquid chromatography (HPLC), causing a falsely high Hb A1c result when using the Bio-Rad D10™ Hemoglobin Analyzer fast Hb A1c Program.
A new unstable hemoglobin (Hb) variant, named Hb Aalesund, was detected during Hb A1c measurement in a patient with a nearly compensated hemolytic anemia. Sequencing of the α-globin genes revealed a 7 bp deletion in exon 3 of the HBA2 gene (HBA2: c.400_406delAGCACCG) (NM_000517.4) causing a frameshift and a premature termination codon (PTC) two positions downstream. Apparently, the transcript bypassed nonsense-mediated decay (NMD), and a truncated protein was translated. The unstable Hb variant presumably underwent rapid denaturation, as heterozygosity of Hb Aalesund was associated with mild hemolytic anemia. In addition, the Hb variant interfered with Hb A1c measurement by cation exchange high performance liquid chromatography (HPLC), causing a falsely high Hb A1c result when using the Bio-Rad D10™ Hemoglobin Analyzer fast Hb A1c Program.
More Related Videos
10:41Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Ion Exchange