Related Experiment Video
Updated: Jan 24, 2026

Author Spotlight: Demonstrating Systematic Endobronchial Ultrasound to New Endoscopists
Published on: August 11, 2023
A novel systematic absence of cross peaks-based 2D-COS approach for bilinear data
Ran Guo1, Xin Zhang2, An-Qi He3
1College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen 518060, PR China; Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, PR China; Beijing National Laboratory for Molecular Sciences, State Key Laboratory for Rare Earth Materials Chemistry and Applications, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, PR China.
Abstract:
A novel approach to use two-dimensional correlation spectroscopy (2D-COS) to analyze bilinear data is proposed. A phenomenon called Systematic Absence of Cross Peaks (SACPs) is observed in a 2D asynchronous spectrum. Two theorems relevant to SACPs have been derived. The SACP-based 2D-COS method has been successfully applied on analyzing bilinear data from mixed samples (including one model system and two real systems). Implicit isolated peaks can be identified and assigned to different components based on characteristic pattern of SACPs even if the time-related profiles of different components are severely overlapped. Based on the results of SACPs, spectra of pure components can be retrieved. Identification of SACPs can still be achieved in the presence of artifacts. Thus, neither noise nor baseline drift can produce significant influence on the results obtained from the approach described in this paper. We have used several well-established chemometric methods, including N-Findr, VCA, and MCR with various initial settings, on two systems that can be successfully solved using the 2D-COS method. The chemometric methods mentioned above cannot provide correct spectra of pure components because of severe problem of rotational ambiguity derived from severe overlapping of the time-related profiles. Only when the information from SACPs in 2D-COS is used as additional constraints in MCR calculation, correct spectra can be obtained. That is to say, the SACP-based 2D-COS method provides intrinsic information which is crucial in the analysis of chromatographic-spectroscopic and analogous data even if the time-related profiles of different components overlap severely.
More Related Videos
Related Concept Videos
Chemical Equilibria: Systematic Approach to Equilibrium Calculations
The first step is to identify all the chemical reactions involved, The...
Cross-Sectional Research
Crossing Over
The homologous pairs of sister chromosomes—one from the maternal and one from the paternal genome—then begin to align alongside each other lengthwise, matching corresponding DNA positions in a process...
Crossed Aldol Reaction Using Weak Bases
Model Approaches for Pharmacokinetic Data: Compartment Models
Two primary types of compartment models are recognized: mammillary and catenary. The more...
Model Approaches for Pharmacokinetic Data: Physiological Models

