Related Experiment Video
Updated: Jan 24, 2026

Phase Contrast and Differential Interference Contrast DIC Microscopy
Published on: August 6, 2008
Myasthenic crisis following iodinated contrast material (iohexol) aspiration: a case report
B V K M Bopeththa1, P B Hewavithana2, H L I Hewapathirana3
1Emergency Medicine, Teaching Hospital Peradeniya, Peradeniya, Sri Lanka. kameerabvkm@gmail.com.
Background:
The number of contrast media-related procedures is ever increasing due to the widespread availability of theoretically safe, low osmolar iodinated contrast material. Although intravenously administered contrast is known to precipitate myasthenic crisis, oral contrast aspiration as a causative factor is not yet documented as such. A 48-year-old Sinhalese man diagnosed as having myasthenia gravis, was evaluated for progressive dysphagia with an upper gastrointestinal contrast study. Iodinated contrast material (iohexol) was used as the contrast medium and there was direct evidence of contrast aspiration during the study. Several minutes after the procedure, severe respiratory distress with evidence of myasthenic crisis requiring intubation and intensive care admission was noted. Treatment with intravenous immunoglobulin, high-dose steroids, and broad-spectrum intravenously administered antibiotics led to an uneventful recovery, although the latter part of the clinical course was complicated with total left lung collapse. Myasthenic crisis can be precipitated by various factors and a successful recovery requires mechanical respiratory support with immunomodulatory and steroid therapy. This is the first reported case that describes the development of myasthenic crisis following iohexol-associated aspiration pneumonitis.
Related Concept Videos
Data Reporting and Recording
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Members Made of Elastoplastic Material
As the bending moment...
Genetic Material

