Comprehensive comparison of multiple quantitative near-infrared spectroscopy models for Aspergillus flavus
Zhengxuan Li1, Xiuying Tang1, Zhixiong Shen1
1College of Engineering, China Agricultural University, Beijing, PR China.
Background:
Aspergillus flavus is a major pollutant in moldy peanuts, and it has a large influence on the taste of food. The secondary metabolites of Aspergillus flavus, including aflatoxin B1 (AFB1) and aflatoxin B2 (AFB2), are highly toxic and can expose humans to high risk. The total mold count (TMC) is an important index to determine the contamination degree and hygiene quality of peanut.
Results:
Quantitative calibration models were established based on full-band wavelengths and characteristic wavelengths, combined with chemometric methods, to explore the feasibility of the use of near-infrared spectroscopy (NIRS) for rapid detection of the TMC in peanuts. The successive projection algorithm (SPA) and elimination of uninformative variables (UVE) algorithms were used to extract the characteristic wavelengths. In comparison, the model built by original spectrum, selected with the UVE algorithm, gave the best result, with a correlation coefficient in a prediction set (RP ) of 0.9577, a root mean square error for the prediction set (RMSEP) of 0.2336 Log CFU/g, and a residual predictive deviation (RPD) of 3.5041.
Conclusions:
The results showed that NIRS is a rapid, practicable method for the quantitative detection of peanut Aspergillus flavus contamination. It is a promising method for detecting moldy peanuts and increasing peanut safety. © 2019 Society of Chemical Industry.
More Related Videos
09:21Inhibition of Aspergillus flavus Growth and Aflatoxin Production in Transgenic Maize Expressing the α-amylase Inhibitor from Lablab purpureus L.
Published on: February 15, 2019
10:24Author Spotlight: Quantification of Aflatoxins and Phytoalexins in Peanut Seeds to Identify Genetic Resistance Against Aspergillus
Published on: April 19, 2024
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
The Sense of Self: Reflected Self-Appraisal and Social Comparison