Feasibility of Fingertip Oscillometric Blood Pressure Measurement: Model-Based Analysis and Experimental Validation
Abstract:
The most commonly used oscillometric upper-arm (UA) blood pressure (BP) monitors are not convenient enough for ambulatory BP monitoring, given the large size of the arm cuff and the compression of UA during the measurement. Finger-worn oscillometric BP devices featuring miniaturized finger cuff have been developed and researched as an alternative solution to the UA-based measurement, yet the reliability of the finger-based measurement is still questioned. To investigate the feasibility of oscillometric BP measurements at the finger position, we performed model-based analysis and experimental validation to explore the underlying issues associated with extending the cuff-based oscillometric approach from UA to other alternative sites. The simulation results revealed that a larger bone-to-tissue volume ratio produced a lower pressure transmission efficiency, which can account for the inter-site measurement discrepancies of mean blood pressure (MBP). We also experimentally compared the oscillometric MBP measurements at UA, middle forearm, wrist, finger proximal phalanx, and finger distal phalanx (FD) of 20 young adults, and each position was matched with a cuff of appropriate size and kept at the same height with the heart. The experimental results demonstrated that FD could be a superior alternative position for oscillometric BP measurement, as it requires the smallest cuff size while providing the most consistent MBP with the UA. Our analysis also suggested that further study is demanded to identify the appropriate oscillometric algorithm for reliable systolic blood pressure and diastolic blood pressure measurements at FD.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...