Hands on Methods for High Resolution Cryo-Electron Microscopy Structures of Heterogeneous Macromolecular Complexes

Marina Serna1

  • 1Structural Biology Program, Spanish National Cancer Research Centre (CNIO), Madrid, Spain.

Summary

Cryo-electron microscopy (cryo-EM) advances enable atomic-resolution structural studies of dynamic macromolecular complexes. New image processing strategies help analyze conformational and compositional heterogeneity in biological samples.

Related Concept Videos

Cryo-electron Microscopy01:28

Cryo-electron Microscopy

Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
4.2K
Electronic Structure of Atoms02:28

Electronic Structure of Atoms


An atom comprises protons and neutrons, which are contained inside the dense, central core called the nucleus, with electrons present around the nucleus. Taking into account the wave–particle duality of electrons and the uncertainty in position around the nucleus, quantum mechanics provides a more accurate model for the atomic structure. It describes atomic orbitals as the regions around the nucleus where electrons of discrete energy exist, characterized by four quantum...
28.3K
Electron Transport Chain: Complex I and II01:46

Electron Transport Chain: Complex I and II

The mitochondrial electron transport chain (ETC) is the main energy generation system in the eukaryotic cells. However, mitochondria also produce cytotoxic reactive oxygen species (ROS) due to the large electron flow during oxidative phosphorylation. While Complex I is one of the primary sources of superoxide radicals, ROS production by Complex II is uncommon and may only be observed in cancer cells with mutated complexes.
ROS generation is regulated and maintained at moderate levels necessary...
18.5K
Assembly of Complex Microtubule Structures01:32

Assembly of Complex Microtubule Structures

Complex microtubule structures are present in resting cells and in dividing cells. In resting cells, they are responsible for maintaining the cellular architecture, tracks for intracellular transport, positioning of organelles, assembly of cilia and flagella. They mediate the bipolar spindle assembly for chromosomal segregation and positioning of the cell division plate in dividing cells. The formation of microtubule complex structures depends on the cell type, cell stage, and cell function.
2.5K
Overview of Electron Microscopy01:25

Overview of Electron Microscopy

The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
13.5K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
5.4K