Related Experiment Video
Updated: Jan 24, 2026

Technical Detail for Robot Assisted Pancreaticoduodenectomy
Published on: September 28, 2019
T-Configuration Horizontal Low-Profile Visualized Intraluminal Support (LVIS Jr) Device-Assisted Coiling for
David Dornbos1, Umang Khandpur1, Patrick P Youssef1
1Department of Neurological Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Background:
Provided certain anatomic considerations, stent-assisted coiling of basilar apex aneurysms can be performed using a single stent placed in a horizontal T-configuration across the aneurysm neck prior to coil deployment, although this has predominantly been described using older-generation stents. The development of the Low-profile Visualized Intraluminal Support (LVIS Jr) device has provided greater versatility than previous stents, including use in smaller vessels, the ability to be resheathed, and improved flow diversion properties.
Methods:
To our knowledge, we report the first use of the LVIS Jr device in a horizontal T-configuration across the aneurysm neck prior to coil deployment in 2 patients for the treatment of basilar apex aneurysms. This technique requires robust posterior communicating artery aneurysms and a second site of vascular access.
Results:
Both patients demonstrated good outcomes following the procedure with no adverse sequelae. One patient required retreatment for recurrence after 1 year and was able to undergo further coiling without difficulty.
Conclusions:
Use of the LVIS Jr device allows greater versatility in horizontal T-configuration stent-assisted coil embolization, when compared with other available intracranial stents. This provides another tool to treat basilar apex aneurysms with improved coil occlusion and a theoretically decreased risk of thromboembolic events.
More Related Videos
05:54Stereo-Electro-Encephalo-Graphy SEEG With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
Published on: June 13, 2016
07:34Microsurgical Venous Pouch Arterial-Bifurcation Aneurysms in the Rabbit Model: Technical Aspects
Published on: May 11, 2011
Related Concept Videos
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configuration of Multielectron Atoms
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...
Introduction to Horizontal Curves