Related Experiment Video
Updated: Jan 24, 2026

Applying an Inducible Expression System to Study Interference of Bacterial Virulence Factors with Intracellular Signaling
Published on: June 25, 2015
Neutralising rivaroxaban induced interference in laboratory testing for lupus anticoagulant (LA): A comparative study
Emmanuel J Favaloro1, Grace Gilmore2, Sandya Arunachalam3
1Department of Laboratory Haematology, Institute of Clinical Pathology and Medical Research, NSW Health Pathology, Westmead Hospital, Westmead, NSW, Australia; Sydney Centres for Thrombosis and Haemostasis, Australia.
Introduction:
Lupus anticoagulant (LA) investigation in patients on anticoagulant therapy is problematic. Rivaroxaban in particular causes significant interference, prolonging both LA screening and confirmation tests, and falsely raising LA screen/confirm ratios, leading to potential false identification of LA. The Russell Viper Venom Time (RVVT) assay, key to the investigation of LA, is especially sensitive to rivaroxaban.
Materials And Methods:
We assessed cross laboratory (n = 82) testing of four samples to investigate whether rivaroxaban induced interference in LA testing could be neutralised. Testing was performed blind to sample type. The samples comprised: (A) A pool of normal plasma (LA-negative control); (B) sample A spiked with rivaroxaban (200 ng/mL) to create rivaroxaban-induced interference (LA 'false' positive sample); (C) sample B subsequently treated with a commercial 'DOAC-neutraliser' (DOAC Stop); (D) sample B treated with andexanet alfa (200 μg/mL).
Results:
As expected, the rivaroxaban-spiked sample (B) caused prolongation of most LA-tests, and also generated a falsely prolonged RVVT screen/confirm ratio (median 1.37, compared to 0.97 for sample A). The sample (C) treated with DOAC Stop evidenced a correction in LA-test clotting times, as well as neutralising the false positive LA (median RVVT screen/confirm ratio of 0.99). Although the andexanet alfa treated sample (D) also yielded a low median RVVT screen/confirm ratio of 0.88, it did not fully correct LA-test clotting times. Consistent with test findings, all laboratories interpreted samples A and C as being LA-negative. For sample B (rivaroxaban), 45.3% identified this as LA positive, and 38.7% identified LA interference. Most (61.3%) also identified sample D as LA negative, with the remainder (38.7%) identifying LA interference.
Conclusions:
DOAC Stop was able to neutralise the false LA activity induced by rivaroxaban, both in terms of clot-times and LA ratios. In contrast, whilst andexanet alfa negated the rivaroxaban-prolonged LA-ratio, it did not fully correct clot-times, leaving some residual LA interference, and requiring additional testing to investigate prolonged clotting times.
Related Concept Videos
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
RNA Interference
This process occurs naturally in cells, often through the activity of genomically-encoded microRNAs. Researchers can take advantage of this mechanism by introducing synthetic RNAs to deactivate specific genes for research or therapeutic purposes. For example, RNAi could be used...
Interference and Diffraction
Serum Laboratory Studies, Stool Test, Breath Test
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Interference and Decay
Interference occurs when competing memories hinder the retrieval of particular information. It can be classified into two types: proactive and retroactive interference. Proactive...

