Detecting Synchronous Thyroid Adenoma and False-Positive Findings on Technetium-99m MIBI Single Photon-Emission
Ji Young Lee1, Hee-Sung Song2, Jae Hyuck Choi3
1Department of Nuclear Medicine, Jeju National University Hospital, Jeju National University School of Medicine, Jeju-si 63241, Korea. easy02000@naver.com.
Abstract:
Technetium (Tc)-99m-methoxyisobutylisonitrile (MIBI) single photon-emission computed tomography/computed tomography (SPECT/CT) is now being used increasingly for preoperative localization of parathyroid adenomas. Tc-99m-MIBI scintigraphy in a 52-year-old man with a diagnosis of primary hyperparathyroidism revealed two focal areas with retention of radioactivity in the left lobe of the thyroid gland on the delayed phase of MIBI SPECT/CT but no significant focal radioactive uptake on MIBI planar images. The patient subsequently underwent left partial parathyroidectomy. Histological analysis identified one lesion to be thyroid hyperplasia and the other to be parathyroid adenoma. This case demonstrates the value of MIBI SPECT/CT for localization of a parathyroid lesion when compared with planar images and that false-positive findings can lead to misdiagnosis in a patient with coexisting thyroid disease. An appropriate diagnostic work-up that includes Tc-99m MIBI SPECT/CT in addition to ultrasonography is helpful for an accurate diagnosis in patients with concomitant thyroid disease.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Design Example: Traverse Angle Computations