Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Measurement of relative lung perfusion with electrical impedance and positron emission tomography: an experimental
1Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.
Background:
Electrical impedance tomography (EIT) with indicator dilution may be clinically useful to measure relative lung perfusion, but there is limited information on the performance of this technique.
Methods:
Thirteen pigs (50-66 kg) were anaesthetised and mechanically ventilated. Sequential changes in ventilation were made: (i) right-lung ventilation with left-lung collapse, (ii) two-lung ventilation with optimised PEEP, (iii) two-lung ventilation with zero PEEP after saline lung lavage, (iv) two-lung ventilation with maximum PEEP (20/25 cm H2O to achieve peak airway pressure 45 cm H2O), and (v) two-lung ventilation under unilateral pulmonary artery occlusion. Relative lung perfusion was assessed with EIT and central venous injection of saline 3%, 5%, and 10% (10 ml) during breath holds. Relative perfusion was determined by positron emission tomography (PET) using 68Gallium-labelled microspheres. EIT and PET were compared in eight regions of equal ventro-dorsal height (right, left, ventral, mid-ventral, mid-dorsal, and dorsal), and directional changes in regional perfusion were determined.
Results:
Differences between methods were relatively small (95% of values differed by less than 8.7%, 8.9%, and 9.5% for saline 10%, 5%, and 3%, respectively). Compared with PET, EIT underestimated relative perfusion in dependent, and overestimated it in non-dependent, regions. EIT and PET detected the same direction of change in relative lung perfusion in 68.9-95.9% of measurements.
Conclusions:
The agreement between EIT and PET for measuring and tracking changes of relative lung perfusion was satisfactory for clinical purposes. Indicator-based EIT may prove useful for measuring pulmonary perfusion at bedside.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Comparing Experimental Results: Student's t-Test
Emission Spectra
Lung Capacity
Bioavailability Study Design: Absolute Versus Relative Bioavailability