Related Experiment Video
Updated: Jan 23, 2026

13:14
Genetic Barcoding with Fluorescent Proteins for Multiplexed Applications
Published on: April 14, 2015
9.7K
Correction: A New Multiplex Assay of 17 Autosomal STRs and Amelogenin for Forensic Application
Plos One
|June 6, 2019
Abstract:
[This corrects the article DOI: 10.1371/journal.pone.0057471.].
Related Concept Videos
The Ratio of X Chromosome to Autosomes
9.5K
In most organisms, sex is determined by the ratio of X and Y chromosomes. However, in some organisms, such as Drosophila and C.elegans, sex is determined by the ratio of the number of X chromosomes to the number of sets of autosomes. The Y chromosome in Drosophila is active but does not determine sex. It contains genes responsible for the production of sperms in adult flies.
Normal male Drosophila has a ratio of one X chromosome to two sets of autosomes. In contrast, normal female...
Normal male Drosophila has a ratio of one X chromosome to two sets of autosomes. In contrast, normal female...
9.5K
Distance Corrections
285
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
285
Power Factor Correction
509
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
509
NMR Spectrometers: Resolution and Error Correction
1.0K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.0K
Photoluminescence: Applications
1.0K
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.0K
Radiation: Applications
1.7K
The average temperature of Earth is the subject of much current discussion. Earth is in radiative contact with both the Sun and dark space; it receives almost all its energy from the radiation of the Sun and reflects some of it into outer space. Dark space is very cold, about 3 K, so Earth radiates energy into it. For instance, heat transfer occurs from soil and grasses, the rate of which can be so rapid that frost can occur on clear summer evenings, even in warm latitudes.
The average...
The average...
1.7K

