Purpose:
The purpose of this study is to evaluate whether a single best image can represent central endothelial cell density (ECD) in corneas of differing cell size coefficient of variance (CV).
Methods:
Four hundred one healthy eyes but with variant CV values were enrolled. For each eye, three nonoverlapping central cornea endothelium images were obtained with Konan NSP-9900 specular microscope. ECD and CV were evaluated by two independent graders using the well-established Center method. Only corneas with high image quality rating (IQR) and ECD >800 cell/mm2 by both graders were included in the study. The study sample was stratified into five CV levels (CV ≤ 35; ≥36; ≥38; ≥40; and ≥45). In each CV level, the ECD agreement, ECD variance, and the correlation between the ECD variation and CV values were analyzed. In addition, the ECD intragrader reproducibility and interframe differences were also analyzed for all levels except CV ≤ 35.
Results:
The study sample includes a total of 278 eyes. High ECD agreement for the two independent graders (intraclass correlation coefficient [ICC] > 0.99), high ECD intragrader reproducibility (ICC > 0.95), low ECD variance (2.0% ± 1.6%, overall), no correlation between the ECD variation and the CV value (P > 0.05), and no significant ECD difference among frames (P > 0.05) was found in any studied CV levels.
Conclusions:
CV does not appear to be associated with ECD variance in the central cornea.
Translational Relevance:
This finding highlights that in healthy corneas but with high CV values, ECD can be reliably analyzed using one single image of best quality.
More Related Videos
10:57Mapping Absolute DNA Density in Cell Nuclei using Single-molecule Localization Microscopy
Published on: November 11, 2025
09:32Clonal Analysis of Embryonic Hematopoietic Stem Cell Precursors Using Single Cell Index Sorting Combined with Endothelial Cell Niche Co-culture
Published on: May 8, 2018
Related Concept Videos
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...
Friedman Two-way Analysis of Variance by Ranks
Variance
The standard deviation measures the spread in the same units as the data....
Central Tendency: Analysis
The mean is one such measure, calculated by totaling all values in a dataset and dividing by the number of values. For instance, the mean blood pressure reading (120, 130, 140, 150) would be 135. However, the mean can be affected by extreme values or outliers.
The median, another measure,...
Measures of Central Tendency
Control Volume and System Representations
The control volume approach considers a stationary region in space through which fluid flows. This region is bounded by a control surface. For instance, in the case of water...