Related Experiment Video
Updated: Jan 23, 2026

High-Resolution Comparison of Bacterial Conjugation Frequencies
Published on: January 10, 2019
Comparison of high-frequency and ultrahigh-frequency probes in chronic inflammatory demyelinating polyneuropathy
Angela Puma1,2, N Azulay3, N Grecu4
1Peripheral Nervous System, Muscle and ALS Department, CHU Nice, Université Côte D'Azur, Nice, France. puma.ar@chu-nice.fr.
Objectives:
High-frequency ultrasound (HFUS 18-20 MHz) performed on patients with chronic inflammatory demyelinating polyneuropathy (CIDP) shows a focal enlargement, particularly in the proximal segments of upper-arm motor nerves. Ultrahigh frequency ultrasound (UHFUS 30-70 MHz), having a higher spatial resolution, enables a better characterization of nerve structures. The aim of this study was to compare the two ultrasound probes in the evaluation of motor nerve characteristics in CIDP patients.
Methods:
Eleven patients with definite or probable CIDP underwent an ultrasound evaluation of median and ulnar nerves, bilaterally. Nerve and fascicle cross-sectional area (CSA), vascularization, and echogenicity were assessed.
Results:
Nerve and fascicle CSA were increased in the proximal segments, especially in the median nerve, in 9/11 patients and in 10/11 patients at the HFUS and UHFUS evaluations, respectively. A statistically significant difference between CSA values obtained with the two probes was found only for fascicle values. UHFUS allowed for a more precise estimation of fascicle size and number than the HFUS. We were able to identify nerve vascularization in 4/11 patients at UHFUS only.
Conclusion:
UHFUS gives more detailed information on the changes in the internal nerve structure in CIDP patients. In particular, it permits to better characterize fascicle size and morphology, and to have a precise estimation of their number. Its frequency range also allows to evaluate nerve vascularization.
Significance:
Ultrasound evaluation could become an adjunctive diagnostic tool for CIDP. Further studies are needed to validate the examined parameters as biomarkers for the evaluation and follow-up of CIDP patients.
More Related Videos
Related Concept Videos
Frequency-dependent Selection
What is a Frequency Distribution
Mean From a Frequency Distribution
When such a data set is encountered,...
Frequency Response of BJT
Low-Frequency Response: At low frequencies, the behavior of the BJT is determined by its DC bias point, which is set by the...
Load-frequency control
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...

