Related Experiment Video
Updated: Jan 23, 2026

Author Spotlight: Advancing Cardiac Procedure Testing Prior to Embarking on Large Animal Studies
Published on: August 25, 2023
Asymmetric Dynamics of the Native Aortic Annulus Evaluated by Force Transducer and Sonomicrometry in a Porcine Model
Leila Louise Benhassen1,2, Diana Mathilde Ropcke3,4, Troels Lading3,4
1Department of Clinical Medicine, Aarhus University Hospital, Skejby, Aarhus, Denmark. benhassen@clin.au.dk.
Purpose:
With new repair techniques of the aortic root and valve emerging, a detailed understanding of the dynamics of the aortic annulus and valve is required for optimal results. The objective of this study was to characterize geometrical changes and force distribution of the native porcine aortic annulus throughout the cardiac cycle.
Methods:
Measurements were performed in an acute 80 kg porcine model (n = 7) using sonomicrometry crystals in the aortic annulus for evaluation of geometry and dynamics, annular force transducer evaluating force distribution, and pressure measurements and echocardiography evaluating valve performance.
Results:
Overall, segmental force distribution and geometrical changes differed between different segments of the aortic annulus. The highest force development was found at the left/right interleaflet triangle (2.87 ± 2.1 N) and the largest segmental expansion was observed at the right-coronary and left-coronary sinus. The aortic annulus changed configuration throughout the cardiac cycle and became more oval in systole.
Conclusions:
This study is the first to describe detailed segmental dynamics and force distribution of the native aortic annulus in a porcine model in vivo. The heterogenous behavior of the aortic annulus suggests that different segments demand different support for repair of the aortic root and valve.
Related Concept Videos
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
Asymmetric Lipid Bilayer
Intermolecular Forces
Self-Evaluation Maintenance Model
Reduction of Alkenes: Asymmetric Catalytic Hydrogenation
The metal catalyst used can be either heterogeneous or homogeneous. When hydrogenation of an alkene generates a chiral center, a pair of enantiomeric products is expected to form. However, an enantiomeric excess of one of the products can be facilitated using an enantioselective reaction or an...
Electromotive Force