Related Experiment Video
Updated: Jan 23, 2026

Induction of Microstreaming by Nonspherical Bubble Oscillations in an Acoustic Levitation System
Published on: May 9, 2021
Comparison of corneal densitometry between big-bubble and visco-bubble deep anterior lamellar keratoplasty
Vincenzo Scorcia1, Valentina De Luca2, Andrea Lucisano2
1Ophthalmology, University of Magna Graecia, Catanzaro, Italy vscorcia@libero.it.
Aims:
To evaluate deep corneal densitometry and visual outcomes after big-bubble (BB-DALK) and visco-bubble (VB-DALK) deep anterior lamellar keratoplasty performed in patients with keratoconus.
Methods:
Prospective comparative study of 50 advanced keratoconic patients who underwent DALK surgery; 25 eyes (group I) were completed with BB-DALK and 25 eyes (group II) with VB-DALK after the failure of pneumatic dissection. Best spectacle-corrected visual acuity (BSCVA), corneal tomographic parameters and endothelial cell count were recorded 1, 3, 6, 12 and 24 months after surgery. Densitometric analysis of the deep corneal interface was obtained using Scheimpflug tomography at each visit; values recorded were compared between the two groups and statistically analysed.
Results:
BSCVA was significantly better in the BB-DALK group than the VB-DALK group (0.39±0.29 vs 0.65±0.23 logarithm of the minimum angle of resolution, respectively) for the first 3 months; and in the same time period, densitometry was significantly higher in the VB-DALK group than those recorded in the BB-DALK group (23.97±5.34 vs 17.13±4.44 grayscale units). However, densitometric values and visual acuity did not differ significantly in the two groups at 1 year. No statistically significant difference for the other variables analysed at any time frame was found.
Conclusion:
The use of viscoelastic substance in the VB-DALK technique may induce modification of interface stromal reflectivity resulting in reduced visual acuity up to 3 months postoperatively. However, this initial negative effect on the interface quality does not affect the long-term visual outcome, with densitometric values and visual outcomes similar in the two groups from 6 months postoperatively.
Related Concept Videos
Excess Pressure Inside a Drop and a Bubble
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Muscles of the Anterior Neck
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...

