Related Experiment Video
Updated: Jan 23, 2026

Objective Nociceptive Assessment in Ventilated ICU Patients: A Feasibility Study Using Pupillometry and the Nociceptive Flexion Reflex
Published on: July 4, 2018
Analyzing ICU Patient Room Environmental Quality Through Unoccupied, Normal, and Emergency Procedure Modes: An EQI
Jennifer A Wagner1, Damon G Greeley2, Thomas C Gormley3
1OnSite-LLC, Prism Environmental Health and Safety, Inc, Discovery Bay, CA, USA.
Background:
There is increasing need to perform invasive surgical procedures in intensive care units (ICUs). Traditional ICUs differ from operating rooms (ORs) in several ways including air changes per hour (ACH) and pressurization. Increased ACH and positive pressurization of ORs intend to provide more aseptic environments for surgery. Development of procedure ready ICUs that transition through unoccupied, occupied, and procedure modes is one solution to improve environmental quality when performing surgery in ICUs. This study assessed the efficacy of two airflow control systems, variable air volume (VAV) and Venturi control, in preventing contaminants from entering ICU from adjacent corridors.
Study Design:
Controlled contaminants, sulfur hexafluoride (SF6) and baker's yeast (CFU/m3), were released in the corridor adjacent to the ICU. SF6 and CFU/m3 were detected inside the ICU at the patient bed during a dynamic simulation of code blue event. VAV and Venturi were compared as they cycled the room through unoccupied, occupied, and procedure modes.
Results:
VAV and Venturi showed significantly fewer CFU/m3 at the patient bed than corridor point of release (p < .05). Although not significant, Venturi cultured 14% fewer CFU/m3 than VAV at the patient bed. There was less SF6 detected at the patient bed with VAV and Venturi (p < .05). There was less SF6 detected at the patient bed with Venturi compared to VAV (p < .05). Venturi transitioned between modes faster than VAV (p < .05).
Conclusion:
Using efficient mode transitioning systems in ICUs may be effective in creating a more aseptic environment that mimics that of the OR.
More Related Videos
Related Concept Videos
Emerging Adulthood
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Normal Distribution
Variation: Normal Distribution, Range, and Standard Deviation