Related Experiment Video
Updated: Jan 23, 2026

Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
Published on: October 24, 2018
Single-Shot Capillary Zone Electrophoresis-Tandem Mass Spectrometry Produces over 4400 Phosphopeptide Identifications
Zhenbin Zhang1, Alexander S Hebert2, Michael S Westphall2
1Department of Chemistry and Biochemistry , University of Notre Dame , Notre Dame , Indiana 46556 , United States.
Abstract:
The dependence of capillary zone electrophoresis (CZE) separations on the charge state of the analyte is useful for the analysis of many post-translational modifications in proteins. In this work, we coupled CZE to an Orbitrap Fusion Lumos Tribrid platform with an advanced peak determination algorithm for phosphoproteomics analysis. A linear-polyacrylamide-coated capillary with very low electroosmotic flow was used for the separation. The optimal injection volume was between 100 and 150 nL of a solution of phosphopeptides in 30 mM ammonium bicarbonate (pH 8.2) buffer, which produces a dynamic pH junction sample injection. Larger injection volumes resulted in serious peak broadening and decreased numbers of phosphopeptide identifications. The optimized system identified 4405 phosphopeptides from 220 ng of enriched phosphopeptides from mouse brain, which represents the state-of-the-art result for single-shot CZE-ESI-MS/MS-based phosphoproteome analysis. We found that the migration time for phosphopeptides is much longer than that for non-phosphopeptides and increased along with the number of phosphorylation sites on the peptides, as expected for the additional negative charges associated with the phosphate groups. We also investigated the phosphorylation site motifs; a number of motifs appeared in the CZE-ESI-MS/MS data but not in LC-ESI-MS/MS data, which suggested the complementary performance of the techniques. The data are available via ProteomeXchange with identifier PXD012888.
More Related Videos
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Hybrid Zones
Mass Spectrometry: Overview

