Smooth or Stepped? Laboratory Comparison of Enhanced Sonifications for Monitoring Patient Oxygen Saturation
Renae Collett, Isaac Salisbury1, Robert G Loeb2
11974 The University of Queensland, St Lucia, Australia.
Background:
The pulse oximeter (PO) provides anesthesiologists with continuous visual and auditory information about a patient's oxygen saturation (SpO2). However, anesthesiologists' attention is often diverted from visual displays, and clinicians may inaccurately judge SpO2 values when relying on conventional PO auditory tones. We tested whether participants could identify SpO2 value (e.g., "97%") better with acoustic enhancements that identified three discrete clinical ranges by either changing abruptly at two threshold values (stepped-effects) or changing incrementally with each percentage value of SpO2 (smooth-effects).
Method:
In all, 79 nonclinicians participated in a between-subjects experiment that compared performance of participants using the stepped-effects display with those who used the smooth-effects display. In both conditions, participants heard sequences of 72 tones whose pitch directly correlated to SpO2 value, and whose value could change incrementally. Primary outcome was percentage of responses that correctly identified the absolute SpO2 percentage, ±1, of the last pulse tone in each sequence.
Results:
Participants using the stepped-effects auditory tones identified absolute SpO2 percentage more accurately (M = 53.7%) than participants using the smooth-effects tones (M = 47.9%, p = .038). Identification of range and detection of transitions between ranges showed even stronger advantages for the stepped-effects display (p < .005).
Conclusion:
The stepped-effects display has more pronounced auditory cues at SpO2 range transitions, from which participants can better infer absolute SpO2 values. Further development of a smooth-effects display for this purpose is not necessary.
More Related Videos
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Solution Equilibrium and Saturation
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Smooth Muscle Contraction
The onset of contraction is triggered by an increase in calcium ions within the sarcoplasm, similar to the process in striated muscle. However, smooth muscles have a relatively smaller reservoir of the sarcoplasmic...
Functions of Smooth Muscles
Function of visceral smooth muscles
Visceral smooth muscle is found in the walls of all hollow organs, except the heart, and is a key player in the involuntary movements that drive the functioning of these internal organs. This tissue is arranged in...