Related Experiment Video
Updated: Jan 23, 2026

Experiments on Ultrasonic Lubrication Using a Piezoelectrically-assisted Tribometer and Optical Profilometer
Published on: September 28, 2015
High-SPL Air-Coupled Piezoelectric Micromachined Ultrasonic Transducers Based on 36% ScAlN Thin-Film
Abstract:
In this paper, air-coupled piezoelectric micromachined ultrasonic transducers (PMUTs) using 36% scandium-doped aluminum nitride (ScAlN) thin-film are presented. ScAlN is known to exhibit higher piezoelectric properties compared to pure AlN leading to significant performance improvements in various piezoelectric micro-electromechanical systems (MEMS) applications including PMUTs. Here, the concentration of Sc in the actual sputtered 1- [Formula: see text]-thick ScAlN film was 36%, which is slightly below the maximum at the phase boundary. The ScAlN PMUTs were fabricated from an SOI wafer, where the dry etching of ScAlN film was optimized. The frequency response and displacement sensitivity of the PMUTs were characterized in the air using laser Doppler vibrometry confirming 2× higher transverse piezoelectric coefficient than AlN. The acoustic transmission and reception of the PMUTs were evaluated from a high-sensitivity microphone and pulse-echo measurements. The PMUTs were designed to operate below 100 kHz in order to mitigate the absorption loss, which resulted in a high transmit pressure of 105-dB sound pressure level (SPL) at 10 cm and only 30-dB attenuation at the 2-m range. Through implementing 36% ScAlN film, the presented PMUTs exhibited a large displacement and consequently, a high SPL compared to the state-of-the-art PMUTs and the bulk transducer considering the size and the excitation voltage.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
07:02Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
Published on: November 14, 2025
Related Concept Videos
Transducer Mechanism: G Protein–Coupled Receptors
GPCRs are also called heptahelical,...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...
G-protein Coupled Receptors
Spin–Spin Coupling: One-Bond Coupling
Transducer Mechanism: Nuclear Receptors
About 48 different soluble family members of nuclear receptors are identified that can be divided into two main classes: