Related Experiment Video
Updated: Jan 23, 2026

A Novel Method for Involving Women of Color at High Risk for Preterm Birth in Research Priority Setting
Published on: January 12, 2018
Blunted sympathoadrenal activation accompanies hemodynamic stability after early ventilation and delayed cord
Joseph J Smolich1,2, Kelly R Kenna3, Jonathan P Mynard3,4,5,6
1Heart Research, Murdoch Children's Research Institute, Parkville, VIC, Australia. joe.smolich@mcri.edu.au.
Background:
As surges in circulating norepinephrine and epinephrine have chronotropic, pressor, and inotropic effects, we tested the hypothesis that blunted rises in these catecholamines during preterm birth accompanied hemodynamic stability observed after early ventilation and delayed cord clamping (DCC), with findings compared to immediate cord clamping (ICC) and a non-asphyxial cord clamp-to-ventilation interval.
Methods:
Anesthetized preterm fetal lambs were instrumented with arterial micromanometers to obtain pressure and the maximal rate of pressure rise (dP/dtmax) as a surrogate of ventricular contractility and an aortic catheter to obtain blood samples for catecholamine assay. Fetuses were delivered and mechanically ventilated before cord clamping ∼1.5 min later (DCC, n = 9) or subjected to ICC with ventilation started ∼40 s later (n = 8).
Results:
Perinatal hemodynamics were stable after DCC, with greater fluctuations evident following birth after ICC (P ≤ 0.05). With DCC, circulating norepinephrine and epinephrine were unchanged after early ventilation but rose following cord clamping (P ≤ 0.01), with concentrations below the threshold for hemodynamic effects. Norepinephrine was higher in the ICC group after cord clamping and immediately after ventilation (P < 0.025), but catecholamine levels were otherwise similar between groups.
Conclusion:
Hemodynamic stability at birth after DCC is accompanied by sub-threshold rises in circulating norepinephrine and epinephrine and thus blunted sympathoadrenal activation.
Related Concept Videos
Birth Control Methods
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
RNA Stability
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Nuclear Stability
To hold positively charged protons together...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...

