Related Experiment Video
Updated: Jan 23, 2026

Recording and Analysis of Circadian Rhythms in Running-wheel Activity in Rodents
Published on: January 24, 2013
Establishing simple image-based methods and a cost-effective instrument for toxicity assessment on circadian rhythm
Gilbert Audira1,2, Bonifasius Putera Sampurna2, Stevhen Juniardi2
1Department of Chemistry, Chung Yuan Christian University, Chung-Li 32023, Taiwan.
Abstract:
Analysis of circadian rhythm behavior alteration in fish for toxicity assessment usually requires expensive commercial equipment and laborious and complicated tweaking. Here, we report a simple setup that consists of a custom-made light box equipped with white and 940 nm light-emitting diode (LED) light strips as light sources, where the locomotion activities of zebrafish or catfish are captured using an infrared-sensitive coupled charged device (CCD). The whole setup was housed in a temperature-controlled incubator to isolate external noise and to maintain consistent experimental conditions. The video recording and light triggering were synchronized using Total Recorder, a recording scheduling software. By using the setup mentioned above and open source software such as ImageJ or idTracker, the locomotion activities of diurnal (e.g. zebrafish) and nocturnal (e.g. catfish) fish during day and night cycles can be quantitatively analyzed. We used simple image-based methods and a cost-effective instrument to assess the circadian rhythm of multiple fish species, as well as other parameters such as age, ambient temperature and chemical toxicology with high precision and reproducibility. In conclusion, the instrument setting and analysis methods established in this study provide a reliable and easy entry point for toxicity assessment on circadian rhythm dysregulation in fish.
Related Concept Videos
Circadian Rhythms and Gene Regulation
Chronopharmacokinetics: Circadian Rhythms and Influence on Drug Response
The time of drug administration is an important factor to consider, as it can influence the toxic dose of a drug. For example, a study conducted by Prins et al. in 1997 examined the effects of the timing of...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Osmoregulation in Fishes
Uncertainty in Measurement: Reading Instruments
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...

