Multifrequency magnetic particle imaging enabled by a combined passive and active drive field feed-through
Dennis Pantke1, Nils Holle1, Akshay Mogarkar1
1Department of Physics of Molecular Imaging, Institute for Experimental Molecular Imaging, RWTH Aachen University, Faculty of Medicine, Aachen, Germany.
Purpose:
Magnetic particle imaging (MPI) allows fast imaging of the spatial distribution of superparamagnetic iron-oxide based nanoparticles (SPIONs). Recent research suggests that MPI furthermore promises in-vivo access to environmental parameters of SPIONs as temperature or viscosity. Various medical applications as nanomedicine, stem cell-based therapies or magnetic hyperthermia could benefit from in-vivo multiparameter estimation by MPI. One possible approach to get access to functional parameters is particle excitation at multiple frequencies. To enable the investigation of the mentioned approach, a novel MPI device capable of multifrequency excitation is needed.
Methods:
MPI usually employs analog band-stop filters to cancel the drive field feed-through, which is magnitudes higher than the particle signal. To enable drive field frequency flexibility over a wide bandwidth, we propose a combined passive and active drive field feed-through compensation approach. This cancellation technique further allows the direct detection of the SPIONs' signal at the fundamental excitation frequency.
Results:
A combined feed-through suppression of up to -125 dB is reported, which allows to adjust the drive field frequency from 500 Hz to 20 kHz. Initial spectroscopic measurements and images are shown that demonstrate the concept of multifrequency excitation and prove the imaging capability of the presented scanner. A mean signal-to-noise ratio (SNR) enhancement by the factor of 1.7 was shown when the first harmonic is used for measurement-based image reconstruction compared to when it is omitted.
Conclusions:
In this paper, the first one-dimensional multifrequency magnetic particle imaging (mf-MPI) that features adjustable excitation frequencies from 500 Hz to 20 kHz is presented. The device will be used to study the principle of multiparameter estimation by employing multifrequency excitation.
More Related Videos
07:01Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
Published on: June 9, 2016
11:12Driving Simulation in the Clinic: Testing Visual Exploratory Behavior in Daily Life Activities in Patients with Visual Field Defects
Published on: September 18, 2012
Related Concept Videos
Motion Of A Charged Particle In A Magnetic Field
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Energy In A Magnetic Field
Take an ideal inductor with zero resistance. Although it's practically impossible, assume that the coil's resistance is so small that it is practically negligible. The loss of the field's energy to dissipate thermal energy (or heat) is thus...